There shouldn't be. That's how it's tested.
Which adapter? Which program? Which platform?
Paul Al;fille
On 1/20/07, Alan Prather [EMAIL PROTECTED] wrote:
Upgraded to 2.6P0 version and am having trouble getting accurate readings
from
my DS18S20 temperature sensors. These are using parasitic
Here's a quick and dirty test with USB, and a bunch of DS18S20s:
amd64:/home/paul/owfs # owserver -u -p 3000
amd64:/home/paul/owfs # for x in `owdir -s 3000` ; do owread -s 3000
$x/temperature ; done
Data error on /bus.0/temperature
Data error on /settings/temperature
Data error on
There shouldn't be. That's how it's tested.
Which adapter? Which program? Which platform?
Paul Al;fille
DS9790r USB adapter
Ubuntu Desktop - Linux Kernel 2.6.17-10
OWFS 2.6p0
libusb 0.1.12
fuse 2.6.1
2- DS18S20-PAR temperature sensors
1- DS2423 counter coresident on the 1wire bus
No
I was/have been getting the same 185F temp from the 18B20 in parasitic
mode IIRC. I think I was testing and seemed to notice that it went
away when powering them vs parasitic. I haven't played with much
lately (been testing pH via the DS2450) but I had a script running that
cycled through
Hello!
Has support ever been included into OWFS for the Java enabled iButton?
For that matter did anyone on this list ever get one to work properly?
I have one. And I've never managed to get it to work properly. It
might be my choice of tools and a lack of sufficient time. Well the
tools for