Re: [Owfs-developers] temperature control

2008-05-20 Thread Jim Kusznir
My apologies; this message got buried If I recall correctly, we tried setting the alarm thresholds on the 18B20's, then execute a syncronous convert, and all the temp sensors show up in alarm, even though their temperature hasn't changed. We tried to continue, in case it was just a temporary

Re: [Owfs-developers] Strange behavior with DS2450

2008-05-20 Thread Paul Alfille
Could you try the embedded CD version to see? 2.6p2 is back from 2/2007. By the way, your code: cat /var/ow/uncached/28.F7668900/power ;echo 1 is a little strange. Paul Alfille On Tue, May 20, 2008 at 11:13 AM, [EMAIL PROTECTED] [EMAIL PROTECTED] wrote: I have a DS2450 that seems to

Re: [Owfs-developers] Strange behavior with DS2450

2008-05-20 Thread [EMAIL PROTECTED]
I didn't realize it had been that long since I updated my OWFS version. I had some down time this afternoon so I compiled 2.7p4. Immediately I noticed the AD read failures seem to have stopped. I've done a couple hundred test reads over a few hours, and I haven't seen any failures so that