Hi,
I just wanted to follow up on this. It this something that could
potentially be fixed, or something I'm doing wrong? I'm afraid I lack
the understanding of the code to understand the nature of the problem or
attempt to patch it myself.
Thanks again,
Charlie
On 02/01/17 10:19, Charlie
Hi Charlie,
If possible and easy for you, it would be great if you can change the BGP
Router ID among the two instances and confirm at least that scenario is
working good for you. I'm meanwhile trying to reproduce the scenario to
see if the issue you raised can be easily fixed.
Cheers,
Paolo
O
Hi Paolo,
sflowtool seems to give good results, but there's is still one problem :
in each sflow sample, I have this :
skipping unknown flow_sample_element: 43874:2 len=16
This causes problems with perl Net::sFlow library, as Flowdata
enterprise: 43874 is not recognized.
I'm unable to trace w