How does the error intensity analysis handle both specification of baseplane RMSD and partly repeated spectrum?

2014-09-12 Thread Troels Emtekær Linnet
Dear Edward. I was wondering how relax handles the error intensity analysis, where one both specify the baseplane RMSD and and one also have partly repeated spectrums? For example you have recorded for 10 time series. You measure the baseplane RMSD for each spectrum. You have repeated

Re: How does the error intensity analysis handle both specification of baseplane RMSD and partly repeated spectrum?

2014-09-12 Thread Edward d'Auvergne
Hi Troels, Currently you can only choose one technique or the other. You will see this in the algorithm for choosing between the different techniques in the pipe_control.spectrum.error_analysis() function (http://www.nmr-relax.com/api/3.3/pipe_control.spectrum-pysrc.html#error_analysis).