Hi Edward,
That is awesome! I will try and let you know if I find any problem.
Thanks so much for taking care of this!
Dhanas
On Feb 3, 2014, at 2:18 AM, Edward d'Auvergne edw...@nmr-relax.com wrote:
Hi Dhanas,
If you have not already seen, I have released relax 3.1.4 which
contains the
Hi Dhanas,
For reference in the mailing list archives
(http://thread.gmane.org/gmane.science.nmr.relax.user/1543), the bug
report is located at https://gna.org/bugs/?21562. To catch this bug,
I will create a relax system test. This will consist of:
- A truncated data set. I think I'll take
Hi Dhanas,
The problem you are seeing is actually because of the relax warnings
starting at:
RelaxWarning: The spin '#2AT7_fmf_mol1:3@N' has been deselected
because of insufficient data.
From looking at the other messages, I am unsure as to why this is not
working. To help solve this problem
Hi,
I am using Relax Ver 3.1.3 on Mac OS. It worked beautifully to calculate the R1
and R2 values using replicated spectra to get the error. But it fails to
calculate NOE if I use replicated spectra for error. It produces empty NOE.out
file. However it works fine if I just use only one set of
4 matches
Mail list logo