On Tue, Feb 21, 2023 at 1:11 PM Toby, Brian H. wrote:
> I am going to make the comment that (A) neutral atom form fact
Now Topas has anisotropy built in the GUI version too. No script is needed.
Peter
Peter Y. Zavalij, PHD
Director - X-ray Crystallographic Center
University of Maryland,
College Park, MD 20742
On Tue, Aug 2, 2022 at 9:16 AM
solution).
Peter
Peter Y. Zavalij
Director - X-ray Crystallographic Center
University of Maryland,
College Park, MD 20742
On Wed, Aug 29, 2018 at 12:38 PM David Elbert wrote:
> Absolutely important that people underst
>From my experience some transition metal oxides, like MoO3, WO3 etc, turns
slowly blue under X-tay, assumedly due to metal reduction.
Peter Zavalij
On May 22, 2017 10:00 AM, "Payzant, E. Andrew" wrote:
> You can run into “interesting” behavior with metastable phases. I once
published data not included in any
database.
Peter Y. Zavalij
Director - X-ray Crystallographic Center
University of Maryland, College Park, M
aryland
On Tue, Jan 10, 2017 at 10:12 AM, Shay Tirosh <stiro...@gmail.com>
as it
is basically beyond the limt of the methods.
Peter
Dr. Peter Y. Zavalij
Director - X-ray Crystallographic Center
University of Maryland, College Park, MD 20832
On Wed, Jul 27, 2016 at 1:07 PM, "Łukasz Kruszewski"
FYI: Kristallografiya was translated into English as Soviet Physics
Crystallography and can be found in many western libraries. Although I am not
sure what year they started translation. Could be after 1966.
Peter Z.
__
Peter Zavalij
Director, X-ray
How about "reciprocal methods" as opposite to "direct methods" which work in
reciprocal space?
Peter
__
Peter Zavalij
Director, X-ray Crystallographic Center
University of Maryland, College Park, MD 20742
http:/www.chem.umd.edu/crystallography
, September 15, 2013 10:05 PM
To: Peter Y. Zavalij; mariomac...@tux.uis.edu.co; rietveld_l@ill.fr
Subject: RE: Instrumental resolution function
Hi Peter, Mario
I happen to have a Ni filter, Cu, LaB6 pattern that has a very similar look to
the one sent by Mario. Probably best to look at the 21.35
...@oit.edu]
Sent: Monday, September 16, 2013 12:08 PM
To: Peter Y. Zavalij; Alan Coelho; mariomac...@tux.uis.edu.co; rietveld_l@ill.fr
Subject: RE: Instrumental resolution function
Alan, Peter,
Would you mind briefly elaborating on the procedure used to fit tube tails? I
personally have only used GSAS
Hi Mario,
The shoulder you observe is what's left from white after it is cut off by
beta-filer. You could check the absorption edge of Ni and it is right at the
shoulder you observe.
Peter
__
Peter Zavalij
X-ray Crystallographic Center
University of Maryland
Maxim,
Generally bond length are not temperature depended (correct me if I am wrong).
So you don't have to do anything if non-ambient means different temperature but
I am not sure about pressure etc.
Peter
__
Peter Zavalij
X-ray Crystallographic Center
University
At the end it is all wrong as we don’t refine individual electrons but
restrained groups that are called “atoms” which are extrapolated with some
average function calculated for free, unbounded atom.
Peter Zavalij
From: rietveld_l-requ...@ill.fr [mailto:rietveld_l-requ...@ill.fr] On Behalf Of
What software is used to convert neutron data in *.bt1 format to any
commonly used format, e.g. GSAS?
Thanks
Peter Zavalij
X-ray Crystallographic Center
University of Maryland
College Park, MD
Office: (301)405-1861
Lab: (301)405-3230
Fax: (301)314-9121
Another book on powder diffraction and rietveld refinement partially based
on GSAS with real examples to follow up the text also describes variety of
quantitative analyses:
http://www2.chem.umd.edu/facility/xray/FPDSCM2.htm
Dr. Peter Y. Zavalij
Director, X-ray Crystallographic Center
Department
One of the reasons could be preferred orientation. If this is the case, one
could derive orientation axis from the ellipsoids.
Peter Zavalij
X-ray Crystallographic Center
University of Maryland
College Park, MD
Office: (301)405-1861
Lab: (301)405-3230
Fax: (301)314-9121
-Original
: Beekman, Matthew [mailto:mbeek...@cas.usf.edu]
Sent: Saturday, March 07, 2009 7:20 PM
To: Peter Y. Zavalij; rietveld_l@ill.fr
Subject: RE: cRs
Hello all,
A quick question regarding the background subtracted R values:
In the .LST file, GSAS gives two sets of values for wRp and Rp: Fitted
Are these flavored comments appropriate for scientific discussion?
Peter Zavalij
-Original Message-
From: Smirnova Olga [mailto:olga.smirn...@hw7.ecs.kyoto-u.ac.jp]
Sent: Sunday, March 08, 2009 5:58 AM
To: Brian H. Toby; rietveld_l@ill.fr
Subject: Re: background subtraction R values
There are others important criteria of refinement quality implemented in
many software but rarely analyzed or published. These are Rp' and Rwp'
calculated with background subtracted from both observed and calculated
data. They are especially important when dealing with high background cases,
e.g.
Kurt,
It looks like incorrect step size (difference between actual step size and
one that is written in the file) or incorrect distance to the detector. The
later may incorrect step size if detector is PSD.
I have similar situation with much smaller difference in peak position but
the shift
FYI: 2nd edition our powder diffraction book has been just released
(paperback):
Fundamentals of Powder Diffraction and Structural Characterization of
Materials. 2nd Edition
Vitalij K. Pecharsky Peter Y. Zavalij, Springer 2009.
See Springer webpage www.springer.com/978-0-387-09578-3 for the book
Kurt,
An old way used for alloys is:
grease the surface of the sample holder (preferably backgroundless) with
some sticky stuff and sieve the powder onto it. The particles will fall down
and stuck at random orientations, unless they are large plates or needles.
Peter Zavalij
Director, X-ray
What is current home page of the Rietveld users' mailing list?
Links that I have are either not valid or mirrors.
Many thanks,
Peter Zavalij
Director, X-ray Crystallographic Center
Department of Chemistry and Biochemistry
091 Chemistry Building
University of Maryland
College Park, MD 20742-4454
Does anyone know how to tell Rietica to account for background (from sample
holder, film, etc.) stored in separate file?
Rietica can do it but there is no much about how to set it up in the manual.
Thanks,
Peter Zavalij
Davide,
Could you perform Rietveld refinement using combined neutron and x-ray data?
This would increase accuracy and the question what is better would
disappear. Basically all you need is both data done at the same temperature.
Also look at neutron and x-ray scattering factors. The neutron
Try out Pow_DLL: http://users.uoi.gr/nkourkou/powdll.htm
It converts practically anything into anything.
Dr. Peter Y. Zavalij
Director, X-ray Crystallographic Center
Department of Chemistry and Biochemistry
091 Chemistry Building
University of Maryland
College Park, MD 20742-4454
Phone: (301
choose Insert
symbol. You could create shortcut to this bar and insert it before 1
P¯1but also you need to select this bar and make font condensed by about
6 pt. The crystallographic 1bar looks like this: 1 .
Peter
Dr. Peter Y. Zavalij
Director, X-ray Crystallographic Center
Department
it.
Pam
*From:* Peter Y. Zavalij [mailto:[EMAIL PROTECTED]
*Sent:* November 15, 2007 9:07 PM
*To:* rietveld_l@ill.fr
*Subject:* Amorphous content
Hi,
I am trying to determine amorphous content using Rietveld refinement
and internal standard. However resulting content of amorphous phase
Ross,
The link to The Gem Dugout X-ray Diffraction Products is
http://www.thegemdugout.com/products.html.
The provide several reference specimens for affordable price, e.g. LaB6 -
$10/g.
And other diffraction products.
Peter
Dr. Peter Y. Zavalij
Director, X-ray Crystallographic Laboratory
Hi,
I am trying to determine amorphous content using Rietveld refinement and
internal standard. However resulting content of amorphous phase is really
unrealistic.
Moreover testing the method using standards with known amorphous content
does not clarify the situation. For example ZnO (NIST, 95%
Tom,
We just replaced Gobel mirror that had the same problem/symptoms. Now we are
back to normal intensity.
Dr. Peter Y. Zavalij
Director, X-ray Crystallographic Laboratory
Department of Chemistry Biochemistry
091 Chemistry Building
University of Maryland
College Park, MD 20742-4454
Phone
. Von Dreele
IPNS Division
Argonne National Laboratory
Argonne, IL 60439-4814
-Original Message-
From: Peter Y. Zavalij [mailto:[EMAIL PROTECTED]
Sent: Tuesday, July 18, 2006 1:52 PM
To: rietveld_l@ill.fr
The best (not the fastest) way is to import observed and calculated
plots from CIF
The best (not the fastest) way is to import observed and calculated plots
from CIF file into Excel spreadsheet and then do to the plot whatever is
desired. Reflections can be shown as error but using imported 2theta.
I have template that does scaling, etc. automatically (to some extend).
Peter
You could do it approximately by introducing atom type with proper seq.
number (no. of electrons).
For example if you have Fe (26 electrons) with 50% occupancy you could use
Al (13 electrons).
It is good enough for powder pattern calculation.
Peter Zavalij
-Original Message-
From: Ana
Very probably you should refine preferred orientation 0,0,1. If it take
place you'll see improved adp's.
Dr. Peter Y. Zavalij University Crystallographer
Materials Research Center, SUNY at Binghamton
Tel: (607)777-4298Fax: (607)777-4623
E-mail:[EMAIL PROTECTED]
http
Windows 2000 does allow to associate many program to the same extension
using "Advance" button.
Dr. Peter Y. Zavalij University Crystallographer
Materials Research Center, SUNY at Binghamton
Tel: (607)777-4298Fax: (607)777-4623
E-mail:[EMAIL PROTECTED]
http://materials.bing
This is strange but Atoms 5 works fine under w2k on my PC.
-Original Message-
From: jools [mailto:[EMAIL PROTECTED]]
Sent: Saturday, December 02, 2000 5:24 AM
To: [EMAIL PROTECTED]
Subject: Atoms 5.0 and Win2000
Does anyone have any experience of getting Atoms v5.0 to run under win2k
To my recollection it is AlB2 structure type:
sp.gr. P6/mmm, a=3 A, c=3.2 A
Al in 0,0,0
B in 1/3,2/3,1/2
Peter Zavalij
-Original Message-
From: Anthony Manerbino [mailto:[EMAIL PROTECTED]]
Sent: Thursday, November 23, 2000 11:54 AM
To: '[EMAIL PROTECTED]'
Subject: TiB2 crystal
Same happens on Windows 2000. Mouse does not work even with DOS mouse
installed.
So I use no mouse. It is still possible...
-Original Message-
From: Davide Levy [mailto:[EMAIL PROTECTED]]
Sent: Tuesday, November 21, 2000 4:30 AM
To: [EMAIL PROTECTED]
Subject: RETRIEVE
Is there anybody
You may use comand line (F4), for example:
V and O and Mn and ELC=3
will give you all compounds containing only V, Mn and O.
See printed manual for other posibilirties.
-Original Message-
From: Habib Boughzala [mailto:[EMAIL PROTECTED]]
Sent: Tuesday, November 21, 2000 12:05 PM
To:
The equation (2) is nothing else but specimen shift in the Bragg-Brentano
geometry.
I have a question concerning the systematic line shifts due to sample
off-centering in the Debye-Scherrer-geometry. The shift D2Theta due to an
eccentricity e in the incident beam direction is always given as