After a second look, I was not 100% accurate on that statement ("This only
occurred on servers where I used SNF_CS_Installer")
One server, where I used the SNF_Installer, did not fail. SNF Code stayed
in place after the AV Update.
Pete: I'll send you my plugin.dat file(s) offline momentarily. There are
some clues which may help.
Regards,
--Paul
From: Message Sniffer Community [mailto:sniffer@sortmonster.com] On Behalf
Of Pete McNeil
Sent: Wednesday, December 05, 2012 9:18 AM
To: Message Sniffer Community
Subject: [sniffer] Re: MDaemon AV 4.1.5 / SNF plugins Update Warning
On 2012-12-05 08:35, Peer-to-Peer (Spam-Filter.com) wrote:
One thing to note: This only occurred on servers where I used
SNF_CS_Installer when originally setting up SNF.
The Servers where I manually added SNF were not affected.
That seems very weird -- how would it know the difference? Any ideas?
_M
--
Pete McNeil
Chief Scientist
ARM Research Labs, LLC
www.armresearch.com
866-770-1044 x7010
twitter/codedweller
#
This message is sent to you because you are subscribed to
the mailing list .
This list is for discussing Message Sniffer,
Anti-spam, Anti-Malware, and related email topics.
For More information see http://www.armresearch.com
To unsubscribe, E-mail to:
To switch to the DIGEST mode, E-mail to
To switch to the INDEX mode, E-mail to
Send administrative queries to