Below are reference links on H2 molecule calculations using WIEN2k:
http://zeus.theochem.tuwien.ac.at/pipermail/wien/2003-October/000880.html
https://www.mail-archive.com/wien%40zeus.theochem.tuwien.ac.at/msg01274.html
https://www.mail-archive.com/wien%40zeus.theochem.tuwien.ac.at/msg08114.html
Has spin-orbit been properly initialized (with the requested magnetization
direction ?
I do not see the symmetry operations from initso in your
struct file (and you do not show your case.in so file).
lapwdm with -so checks the symmetry (needs to do a symmetrization of the dmats)
and will
Dear Wien users,
I attempted to run LDA+U calculation with a simplified structure of
Sr2IrO4 (case.struct is appended). I am having problem at the lapwdm
step when both -so and -orb are turned on. In fact, there appeared to
be no error if I run with only the -orb option (no spin-orbit
coupling).
Adding -hf switch to joint did the trick, works like a charm now.
Thank you
Pavel
-- Původní zpráva --
Od: t...@theochem.tuwien.ac.at
Komu: A Mailing list for WIEN2k users wien@zeus.theochem.tuwien.ac.at
Datum: 15. 6. 2015 21:47:49
Předmět: Re: [Wien] optic with hf
Hi,
You need
dear wien2k users
I want to run c/a optimization (constant volume) on a compound which its origin
structure is cubic now i have some questions:
1- I know its cubic spacegroup but for c/a optimization in StructGen, i must
create its tetragonal structure or cubic space group is correct and
Dear Wien2k mailing list,
what is the needed procedure to run optic after hybrid calculation?
I've tried:
x lapw2 -hf -fermi
x optic -hf
after run_lapw -hf -p succesfully finished (calculated :GAP value is
looking good, when compared to plain PBE), however the dielectric function
does not
Dear Gavin,
Thanks a lot!!!...It will be very helpful for us.
with regards,
On Mon, Jun 15, 2015 at 8:48 PM, Gavin Abo gs...@crimson.ua.edu wrote:
Below are reference links on H2 molecule calculations using WIEN2k:
Hi,
You need -hf for joint as well: x joint -hf
F. Tran
On Mon, 15 Jun 2015, pavel.ondra...@email.cz wrote:
Dear Wien2k mailing list,
what is the needed procedure to run optic after hybrid calculation?
I've tried:
x lapw2 -hf -fermi
x optic -hf
after run_lapw -hf -p succesfully finished
Did you really mean to run with a U of 32eV? Or did you intend to use
2.4eV, I.e. 0.176 in case.inorb?
---
Professor Laurence Marks
Department of Materials Science and Engineering
Northwestern University
http://www.numis.northwestern.edu
Corrosion in 4D http://MURI4D.numis.northwestern.edu
Dear wien2k users,
We need to calculate the total energy of H2
molecule. Is there any reference in which it has been done using the code
wien2k...or is there any guideline to do so?...
Any response in this regard will be helpful for us.
Thanks in advance,
with
You have to change the symmetry to tetragonal, change the c parameter by 0.001
and the program will recognize that it is not cubic.
De: wien-boun...@zeus.theochem.tuwien.ac.at
wien-boun...@zeus.theochem.tuwien.ac.at en nombre de Seyyed Amir Abbas Emami
11 matches