11.11.2016 02:06, Abderrahmane Reggad wrote:
my question is about the determination of the magnetic
ground state .
Is it necessary the minimization of the atomic positions for this purpose?
When you make a calculation you take _a_model_ instead of an actual
sample. The choice of the model
10.11.2016 21:33, Dr. K. C. Bhamu wrote:
I am using 5% rmt reduction and after reducing rmt by 5% rmt for both Pb
and I it remained same (2.5) so during initialization. So, I reduced rmt
for "I" by 0.2/0.3 manually.
Can I do this??
I cannot understand your message, I am afraid nobody can.
> I
At first I would have guessed that you run out of memory (need more
cores for 300 atom cells). However, the error message points to the fact
that already lapw1 had a problem. Disk space ?? Or the scratch file
system was changed on your batch job
Try to repeat it with lapw1/lapwso in the
Do you think the ground state is the state with arbitrarily choosen positions
of the atoms ?
Ciao
Gerhard
DEEP THOUGHT in D. Adams; Hitchhikers Guide to the Galaxy:
"I think the problem, to be quite honest with you,
is that you have never actually known what the question is."
Dear Gerhard
Yes I did but my question is about the determination of the magnetic ground
state .
Is it necessary the minimization of the atomic positions for this purpose?
Best regards
--
Mr: A.Reggad
Laboratoire de Génie Physique
Université Ibn Khaldoun - Tiaret
Algerie
Did you read the manual about how to do both at once ?
Ciao
Gerhard
DEEP THOUGHT in D. Adams; Hitchhikers Guide to the Galaxy:
"I think the problem, to be quite honest with you,
is that you have never actually known what the question is."
Dr. Gerhard H.
Hello again
I am still waiting for any answer for my query .
every effort will be helful
Best regards
--
Mr: A.Reggad
Laboratoire de Génie Physique
Université Ibn Khaldoun - Tiaret
Algerie
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
Dear Prof. Peter
I am using 5% rmt reduction and after reducing rmt by 5% rmt for both Pb
and I it remained same (2.5) so during initialization. So, I reduced rmt
for "I" by 0.2/0.3 manually.
Can I do this??
Sincerely
Bhamu
___
Wien mailing list
ohhh, sorry Prof. Peter.
(sp) was included by mistake. I forgot to delete it.
For Pb(5p): When I initialized the case I for one 5P state as core(T) and
other as valance (F).
The total charge leakage (not in the initialization bu it was observed in
the *.outputst file) was 0.00068 with -6.0 ecut
Why would you do a runsp_lapw for a non-magnetic system ???
Spin-orbit is also active for a non-magnetic material.
Don't mix up spin-polarization with spin-orbit
PS: I'm also not sure why you want to include the Pb-5p state as valence
?? I don't think you have to use so small Pb spheres
Thank you Professor Peter and McLeod for your nice explanation.
I have to go through the paper and then I can make a better statement.
You are right Mcleod, it is orthrohombic MAPbI3 structure.
Dear Prof. Peter,
It is reported by Tran that mBJ is not good for effective masses:
check your k-list
check if the three integers defining the k-points and the multiplier are well
separated
in some cases one has problems with the formatted output in the k-list when
using large number of k-points
Ciao
Gerhard
DEEP THOUGHT in D. Adams; Hitchhikers Guide to the Galaxy:
"I think
Very good explanation.
So you should probably use SO + mBJ and see what comes out then
(you should get again a good band gap, although effective masses are not
necessarily improved by mBJ ...)
Am 10.11.2016 um 15:24 schrieb John McLeod:
I have some experience using WIEN2k for metal
Dear Wien2k and XCrySDen,
I am working on FCC compounds (which have four atoms in a unit cell) with
Wien2k code. To get Fermi surface i used 44x 44x 44 K-mesh, which will
create 2168 k points in the Brillouin Zone. With this number of K points, i
get smooth Fermi surfaces.
After this, i created
I have some experience using WIEN2k for metal organic halide perovskites.
PBE without SOC gets the correct band gap for CH3NH3PbI3 (which I assume
is the compound Dr. Bhamu is studying) because of a "fortuitous" error
cancellation between using PBE and ignoring SOC. This is reasonably well
a) You must not ignore warnings of nn (and of sgroup).
b) If you do and continue the initialization until it stops, it has
created a wrong case.inst file, and thus this file must be removed
again before you make a new trial (or make a new directory and copy just
the case.struct file. So
I'm not the expert on that topic, but I think you mix up the two
dielectric constants, which could be a semantic problem. To compare with
a classic experiment, you may need to obtain the ionic contribution to
the dielectric constant, which as far as I know can be done using BERRYPI.
Other
Dear GM Rai,
will you please send me your directory with the case LiGaTe?
I will try to run x lapw5 manually from terminal.
Tomas
"
Dear Tomas,
Thanks, for your kind reply, we tried for 3 3 3, but the result is same.
Actually, we have made good orthorhombic structure of LaMnO3,
Dear Azam
Do you think that the adding of SO coupling will reduce the value of the
found gap (1.3 ev ) to the exeperimental value of 0.1 eV.
Best regards
--
Mr: A.Reggad
Laboratoire de Génie Physique
Université Ibn Khaldoun - Tiaret
Algerie
___
Wien
Dear Wien2k Prof. Blaha and other Wien2k experts,
To put a joint paper on complex Metal-organic halide perovskites, I am
trying to reproduce some experimental results measures by my collaborator.
For my complex system, I got low frequency dielectric constant value of
~5.6 and the calculated the