[Wien] Problem about -band option in lapw2

2013-06-21 Thread 万博
Dear Wien2k users, According to UG, -band opt is valid in lapw2.However, when I try to run: x lapw2 -band -alm It gives the error looks like: [bwan@physicshpc NiO]$ cat lapw2.error Error in LAPW2 'FERMI' - number of k-points inconsistent when reading kgen 'FERMI' -

Re: [Wien] Problem about -band option in lapw2

2013-06-21 Thread Peter Blaha
The option -band is working with lapw2, but NOT together with -alm. Its normal usage is just to create case.qtl for band-plotting. If you really need -alm, set FERMI-method to ROOT in case.in2. On 06/21/2013 08:47 AM, 万博 wrote: Dear Wien2k users, According to UG, -band opt is

[Wien] need help on plotting band structure

2013-06-21 Thread venkatesh chandragiri
Dear Wein2k users, i have successfully runs the Spaghetti calculations after getting spin polarized scf convergence using following commands for 16 atomic based primitive unit cell, x lapw1 -band -c up/dn x irrep -up/dn x lapw2 -band -qtl -c -up/dn Edit case.insp x spaghetti -up/dn I need

Re: [Wien] Optimize b/a ratio but didn't get the option to plot it

2013-06-21 Thread shamik chakrabarti
Dear wien2k users, I have solved the above problem. I have plotted data of case.analysis file and done a polynomial fit in Origin. It is giving a smooth minima. Thanking you, with regards, On Fri, Jun 21, 2013 at 7:23 AM, shamik chakrabarti shamik...@gmail.comwrote: Dear wien2k

[Wien] Why unit cell energy is same on increasing pressure ? and Band gap problem with pressure.

2013-06-21 Thread Zaid
Respected Wien2k users I am studying pressure dependent study for the first time. On increasing pressure from 0 to 30 GPa with a step of 10GPa, I got almost same unit cell enrergy for 0, 10, 20, 30 GPa. Why it is same ? May anyone explain . Also band gap should increase with increase in pressure

Re: [Wien] Why unit cell energy is same on increasing pressure ? and Band gap problem with pressure.

2013-06-21 Thread Stefaan Cottenier
I am studying pressure dependent study for the first time. On increasing pressure from 0 to 30 GPa with a step of 10GPa, I got almost same unit cell enrergy for 0, 10, 20, 30 GPa. Why it is same ? May anyone explain What is your definition of 'almost'? In that pressure range, total energy

[Wien] mBJLDA

2013-06-21 Thread sudhir kumar
Dear Prof. Blaha, in fact the C parameter of the mbjLDA depends on the material density therefore it has to be different value for the different materails. Well, one can interpolate the value of C for the alloys system. Could you pl. tell me the name of the file where it had been written which

Re: [Wien] Why unit cell energy is same on increasing pressure ? and Band gap problem with pressure.

2013-06-21 Thread Zaid
Thank you Sir. Kindly have a look at the collected data below so that you can understand my problem. This data is for a AB2C4 type spinel compound. Would you explain this unit cell energy trend ? Also as you can see band gap starts increasing slightly with the pressure after a certain limit. In

Re: [Wien] Why unit cell energy is same on increasing pressure ? and Band gap problem with pressure.

2013-06-21 Thread Fecher, Gerhard
Your lowest energy is at 10GPa, But the energy from the Birch Murnagham fit should be lowest at 0GPa Or was there some typo in the table, or did you use different functionals to compare the energies Note that you should not compare total enegies from mBJ and/or LDA+U with different size of U

Re: [Wien] Why unit cell energy is same on increasing pressure ? and Band gap problem with pressure.

2013-06-21 Thread Zaid
Sir, Energies are calculated with GGA only. The second issue is seperate, which is about energy Band Gaps. Band gaps are calculated with mBJ-GGA and GGA+U. Still not clear about these anomalic trends in first and second issue ? Thank you for your kind attention. On Fri, Jun 21, 2013 at 11:51 PM,

Re: [Wien] Why unit cell energy is same on increasing pressure ? and Band gap problem with pressure.

2013-06-21 Thread Zaid
Sir, Unit cell Energies are calculated with GGA only. The second issue is seperate, which is about energy Band Gaps. Band gaps are calculated with mBJ-GGA and GGA+U. Still not clear about these anomalic trends in first and second issue ? Thank you for your kind attention. On Fri, Jun 21, 2013 at

[Wien] The Wien2wannier

2013-06-21 Thread mourad boujnah
Hello all wien2k users I start to install wien2wannier it has installed without error, i follow the step in userguide but that give me the follow inf erro. Please some one help me and thank you in advance. Mourad@linux-tfwb:~/WIEN2k/Mourad/cr init_w2w continue with wannier90.x or restart