[Wien] Broadening error in TELNES3

2017-01-05 Thread Atsushi Yamaguchi
Dear WIEN2k users, An error occurs in x broadening of TELNES3 in WIEN2k_16.1. The details of the error are as follows. 0 lines1014 lines forrtl: severe (59): list-directed I/O syntax error, unit 47, file /net/h86/WIEN2k/STO-test/STO-test.elnes Image PC

[Wien] Question about symmetry of detector position in TELNES calculation

2015-04-15 Thread Atsushi Yamaguchi
I have a question about setting DETECTOR POSITION for TELNES. TELNES has a keyword DETECTOR POSITION with two parameters, theta_x and theta_y, and I'm using this to analyze the scattering angle dependency of EELS. When the crystal has symmetric rocksalt structure, the intensity