Dear Wien2k mailing list,
the case.scf2 file contains the GAP value, can I find somewhere in the scf*
or output* files also the two kpoints corresponding to this gap, eg.
positions of the bottom of the conduction band and top of the valence band?
I can of course plot the band structure or go
-- Původní zpráva --
Od: emami seyyed amir abbas
Komu: wien@zeus.theochem.tuwien.ac.at
Datum: 15. 10. 2016 11:18:32
Předmět: [Wien] optic (transitions)
"
Dear users
I obtained dielectric function curve (both real and imaginary). There are
some peaks in
Dear Wien2k mailing list,
just wondering if it is possible to calculate also the off-diagonal tensor
components with the BSE module (I'm specifically interested in the xz
component for a monoclinic cell). No matter what I tried I can only get the
diagonal xx, yy and zz components.
Did anyone
-- Původní zpráva --
Od: Peter Blaha
Komu: A Mailing list for WIEN2k users
Datum: 29. 1. 2016 12:18:58
Předmět: Re: [Wien] force difference between LAPW and PAW method
"If the disordered compound goes metallic ???
-- Původní zpráva --
Od: Laurence Marks
Komu: A Mailing list for WIEN2k users
Datum: 29. 1. 2016 13:34:23
Předmět: Re: [Wien] force difference between LAPW and PAW method
"
Did you check the absolute cell size for the
-- Původní zpráva --
Od: Peter Blaha
Komu: A Mailing list for WIEN2k users
Datum: 29. 1. 2016 12:56:20
Předmět: Re: [Wien] force difference between LAPW and PAW method
"Maybe one should use in VASP also a PAW
Dear Wien2k mailing list,
recently I've become interested in calculating XPS shifts for some TiO2-
based compounds. For some initial testing I've took plain rutile and
anatase, made a supercells around 100 atoms and calculated shifts of core O
1s state to get familiar with the process. I've
Adding -hf switch to joint did the trick, works like a charm now.
Thank you
Pavel
-- Původní zpráva --
Od: t...@theochem.tuwien.ac.at
Komu: A Mailing list for WIEN2k users wien@zeus.theochem.tuwien.ac.at
Datum: 15. 6. 2015 21:47:49
Předmět: Re: [Wien] optic with hf
Hi,
You need
Dear Wien2k mailing list,
what is the needed procedure to run optic after hybrid calculation?
I've tried:
x lapw2 -hf -fermi
x optic -hf
after run_lapw -hf -p succesfully finished (calculated :GAP value is
looking good, when compared to plain PBE), however the dielectric function
does not
I was looking into this and the filtvec approach seems to be the most
promising.
What I was trying to do was select one bandindex with filtvec, than run lapw
2 and get clmval file, use mixer to get clmsum file and finally use aim to
get the charge distribution over atomic basins.
My test cases
Thanks a lot for all the ideas.
Using another code is not an option, since I already have a lot of large
cases computed with Wien2k, so that would be a huge amount of work to redo
that. On the other side, I don't probably need the exact numbers, basically
what I would like to do is some graphs
Hi,
I guess you are using gcc or some other non intel compiler...
This is a syntax that works with ifort but is not a part of the fortran spec.
You can make it work by replacing the (1X, ,I10) with (9X,I10)
But I'm not a fortran expert, so I'm not 100% sure if this is indeed equivalent.
12 matches