On Tue, Oct 19, 2010 at 12:24 PM, Marc Kleine-Budde <m...@pengutronix.de>wrote:

> On 10/19/2010 06:12 PM, Jargalan Nermunkh wrote:
> >> You mean without the patches mentioned above, I mean the unpachted
> >> 2.6.35.x, your can controller was missing frames? After applying these
> >> patches that problem was fixed?
>
> > That is correct. The patch added proper handling of RX1 when there is a
> > rollover from RX0 to RX1.
>
> Hmmm, does it? But it's good as it improves your situation.
>
> >> Can you ensure with a 3rd system, preferred with a different CAN core,
> >> that the frames send to the bus are correct?
>
> > I connected a board to a lawicel CAN dongle and receiving on the board
> > (sending from dongle) is fine but sending (with cangen) from the board to
> > the dongle produces repeated frames.
>
> We're talking about sending on the mc251x? This is even a different
> problem.
>

Yes this is a different problem.


>  >> Which driver is active in your setup? Does this happen with both
> >> versions of the driver?
> >>
> >
> > I am currently using the inline driver.
>
> What do you mean? Are you using net-next-2.6/master with my series
> applied or 2.6.35.x?
>

I am a bit new to this sorry about the confusion. I am using 2.6.36-rc4
found here:
http://arago-project.org/git/people/?p=sneha/linux-davinci-staging.git;a=shortlog;h=refs/heads/davinci-spi-rewrite

cheers,
> Marc
>
> --
> Pengutronix e.K.                  | Marc Kleine-Budde           |
> Industrial Linux Solutions        | Phone: +49-231-2826-924     |
> Vertretung West/Dortmund          | Fax:   +49-5121-206917-5555 |
> Amtsgericht Hildesheim, HRA 2686  | http://www.pengutronix.de   |
>
>
-- 
Jargalan Nermunkh
_______________________________________________
Socketcan-users mailing list
Socketcan-users@lists.berlios.de
https://lists.berlios.de/mailman/listinfo/socketcan-users

Reply via email to