hello old SI-world


i have a problem with the gear_mc-riggingtool which i don't understand.
I have already reinstalled SI (running on Win10) I have changed the PC no succes.

It had worked wonderfully at the beginning of the year with another character (it was even more complex than this one) but it was Win7!
Where I get the error now is when I jump between FK/IK with the switch button.
Especially it is only the right leg.
Both, independently defined and mirrored rigs have this problem and this rig is simple
controller-controller-spine-LeftLeg and rightleg.
Just received the following error message


SelectObj "rig.global_C0_ctl"
' ERROR : Traceback (most recent call last):
' File "<Script Block 2>", line 294, in gear_PSet_leg_L1_ikfkSwitch_OnClicked
' switcher.switch()
' File "P:\workgroup_2014\Rigging\Application\Plugins\..\Modules\gear\xsi\rig\component\logic.py", line 248, in switch
' self.switchToIk()
' File "P:\workgroup_2014\Rigging\Application\Plugins\..\Modules\gear\xsi\rig\component\logic.py", line 308, in switchToIk
' a = self.roll.Value + (dDirectionDot/abs(dDirectionDot)) * dAngle
' ZeroDivisionError: float division by zero
' - [line 293 in C:\Program Files\Autodesk\Softimage 2015 SP2\Application\bin\sisetpluginvars.py]
' ERROR : Property Page Script Logic Error (Python ActiveX Scripting Engine)
' ERROR : [291] def gear_PSet_leg_L1_ikfkSwitch_OnClicked():
' ERROR : [292] prop = PPG.Inspected(0)
' ERROR : >[293] switcher = logic.IKFKSwitcher(prop.Model, prop.Parent3DObject, 'leg_L1', True, False)
' ERROR : [294] switcher.switch()
' ERROR : [295] PPG.Refresh()
' ERROR : Traceback (most recent call last):
' File "<Script Block 2>", line 294, in gear_PSet_leg_L1_ikfkSwitch_OnClicked
' switcher.switch()
' File "P:\workgroup_2014\Rigging\Application\Plugins\..\Modules\gear\xsi\rig\component\logic.py", line 248, in switch
' self.switchToIk()
' File "P:\workgroup_2014\Rigging\Application\Plugins\..\Modules\gear\xsi\rig\component\logic.py", line 308, in switchToIk
' a = self.roll.Value + (dDirectionDot/abs(dDirectionDot)) * dAngle
' ZeroDivisionError: float division by zero
'


but with this error it now runs without errors .
Even if I check the guide before with "update Guide" I don't get an error displayed.

Very strange and confusing

If someone had something similar or knows a workaround, my SI life is fun again.

many thanks in advance


Walt

------
Softimage Mailing List.
To unsubscribe, send a mail to softimage-requ...@listproc.autodesk.com with 
"unsubscribe" in the subject, and reply to confirm.

Reply via email to