On Sat, Jun 12, 2010 at 09:35:46PM -0700, Brad wrote:
> How were the trays shut down? 
> Usually the controllers are shut down first then the shelves.

I'm pretty sure they were shut down incorrectly.

> It sounds like they we shut down incorrectly - you'll have to
> escalated to Sun so they can backline to LSI to rebuild the volumes.

We have a support contract with Sun and they're on top of things. But
seriously, an array that loses it's config because you shut down the
trays in an incorrect order seems so lame, especially one that costs
tens of thousands of dollars.

-- 
albert chin (ch...@thewrittenword.com)