Please send messages to the help list, not me directly.

I believe the doc/tutorial covers how to use the
ADC interfaces and the oscilloscope program.

Basically you should be able to replace VoltageC,
or even DemoSensorC itself, with anything that
provides the ADC interface, such as Photo or Temp
(which may be mica specific...not sure...I see
that my telos directory has a HumidityC.nc file).
Since I don't use Tos2 I'm not sure what they've
called everything.

MS

Aravind S wrote:
> Hi,
> 
> I am a final year M.Tech student of Cochin University of Science and 
> Technology in Vlsi and Embedded systems.As a part of my M.Tech project I 
> need your help in the following topic:
> 
> I am new to tinyos . I have run the oscilloscope  app. with two telosb 
> 2420. It seems to work fine but displays a constant  line graph.
> 
>  
> 
>  I want to now use the light , temperature sensors to display on  graph 
> AND display the value on LINUX terminal.I am using tinyos-2.x installed 
> on linux(RHEL 5.4). 
> 
>  
> 
> Checking DemoSensorC.nc  shows VoltageC as DemoSensor. How can 
> this  be  changed this to light or temp?
> 
>  
> 
> Please send me the source code.
> 
>  
> 
> Eagerly waiting for your replay
> 
>  
> 
>  Thanks
> 
>  
> 
> Aravind.S
> 
> CEC CUSAT
> 
> Kerala
> 
> India
> 
_______________________________________________
Tinyos-help mailing list
Tinyos-help@millennium.berkeley.edu
https://www.millennium.berkeley.edu/cgi-bin/mailman/listinfo/tinyos-help

Reply via email to