Hi,
We are experiencing problems with sequence numbers that get out of sync.

We have experimented with changing throughput and max-pending-submits, but this does not always seem to resolve the issue.

Has anyone had similar problems and found a solution?

The bearerbox log message we receive is:
2005-08-10 16:20:37 [1648] [8] WARNING: SMPP[XXXXX]: SMSC sent submit_sm_resp with wrong sequence number 0x0000318b

Our configuration for this SMSC is:

#
# Group: smsc
#
priority=3
system-type=smpp
system-id=
group=smsc
smsc-id=XXXXX
smsc=smpp
service-type=
#msg-id-type=1
source-addr-ton=1
source-addr-npi=1
source-addr-autodetect=0
host=XXXXXXXX
smsc-username=XXXXX
port=31000
smsc-password=XXXXXX
throughput=6
max-pending-submits=50
data-coding-scheme=-1
reconnect-attempts=1000
interface-version=34
message-retry-attempts=100
dest-addr-npi=1
dest-addr-ton=1
transceiver-mode=1
reconnect-delay=60
denied-prefix=XXXXXXXX
allowed-prefix=
denied-smsc-id=XXXXXXX
preferred-smsc-id=XXXXXX
enquire-link-interval=60

Reply via email to