Maybe it has to do with system type parameter. You have it empty here,
meanwhile it maybe configured at the smsc side. Ask from them what is system
type name.

On Thu, Nov 19, 2009 at 5:33 PM, Stéphane Bruno <mysubscription...@gmail.com
> wrote:

> Hello all,
>
> I am trying to connect to an SMSC using SMPP 3.4. I am receiving the
> following error:
>
> [7] ERROR: connect failed
> 2009-11-19 11:30:28 [2889] [7] ERROR: System error 22: Invalid argument
> 2009-11-19 11:30:28 [2889] [7] ERROR: error connecting to server
> `IP_ADDRESS' at port `3717'
> 2009-11-19 11:30:28 [2889] [7] ERROR: SMPP[voila]: Couldn't connect to
> server.
> 2009-11-19 11:30:28 [2889] [7] ERROR: SMPP[voila]: Couldn't connect to
> SMS center (retrying in 10 seconds).
>
> Here is my config for the SMSC:
>
> group = smsc
> smsc = smpp
> host = IP_ADDRESS
> smsc-id = AN_ID
> allowed-smsc-id = AN_ID
> port = 3717
> #receive-port =
> our-host = MY_HOST_NAME
> smsc-username = USERNAME
> smsc-password = PASSWORD
> system-type =
> transceiver-mode = true
> #service-type =
> interface-version = 34
> #address-range =
> my-number = 7464
> source-addr-ton = 1
> dest-addr-ton = 1
> #bind-addr-ton = 1
> source-addr-npi = 1
> dest-addr-npi = 1
> #bind-addr-npi = 1
> source-addr-autodetect = false
> #alt-charset =
> log-file = "/var/log/kannel/voila.log"
> log-level = 1
>
> Please help!
>
> Stéphane
>
>

Reply via email to