Split your single bind into two separate binds (one with port only and one with receive-port only) this will solve your problem.
On 3 July 2017 at 14:43, Dave <d...@eth0.ch> wrote: > Hi all, > > does anyone knows this behaviour? > > The SMPP link is online for many days and after a reconnect (from the > provider?) the link shows it is online but no messages are going through > it. They are re-routed by Kannel internally through a different link. > > We experience this with two independent SMPP providers. However, it does > not happen on every automatic reconnect. Could it be a configuration issue? > > group = smsc > smsc = smpp > smsc-id = <name1> > allowed-smsc-id = >name1>;<name2> > preferred-smsc-id = <name1> > host = <ip> > port = 2775 > receive-port = 2775 > smsc-username = <user> > smsc-password = <pass> > system-type = "DIR" > throughput = 10 > dest-addr-ton = 2 > dest-addr-npi = 1 > bind-addr-ton = 1 > bind-addr-npi = 1 > > > group = smsc > smsc = smpp > smsc-id = <name2> > allowed-smsc-id = <name2>;<name1> > preferred-smsc-id = <name2> > host = <ip> > port = 2775 > receive-port = 2775 > smsc-username = <user> > smsc-password = <pass> > system-type = "CMT" > throughput = 10 > > > Thanks for input, David. > > -- Donald Jackson http://www.ddj.co.za