You are running out of memory. You cannot run 70x30x30 unit cells on a PC and in sequential mode.
Am 22.12.2015 um 22:00 schrieb Hu, Wenhao:
Hi, All: I met a problem in the initialization stage. I’m currently testing the effect of distance between clusters in nano wire calculation. When the distance is small (size of unit cell is small), everything is initialized properly. When I increase the distance until the size of unit cell is as large as 70x70x30 in bohr, I met the following problem: dstart -c -p (14:31:23) running dstart in single mode Segmentation fault 13.207u 0.136s 0:13.62 97.8% 0+0k 0+18312io 0pf+0w error: command /Users/wenhhu/wien2k14/dstartpara -c start.def failed Can anyone tell what is this error? And How can we solve it? Best, Wenhao _______________________________________________ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
-- -------------------------------------------------------------------------- Peter BLAHA, Inst.f. Materials Chemistry, TU Vienna, A-1060 Vienna Phone: +43-1-58801-165300 FAX: +43-1-58801-165982 Email: bl...@theochem.tuwien.ac.at WIEN2k: http://www.wien2k.at WWW: http://www.imc.tuwien.ac.at/staff/tc_group_e.php -------------------------------------------------------------------------- _______________________________________________ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html