Hi,

You don't need to do any calculation before the one with LB94.
When initialization (init_lapw) is completed, modify case.in0
by choosing:
EX_PBE EC_PBE VX_LB94 VC_NONE

If you are only interested in the band gap, it does not matter
what you choose for EX and EC.

FT

On Tuesday 2017-05-02 06:57, Subrata Jana wrote:

Date: Tue, 2 May 2017 06:57:41
From: Subrata Jana <subrata.j...@niser.ac.in>
Reply-To: A Mailing list for WIEN2k users <wien@zeus.theochem.tuwien.ac.at>
To: wien@zeus.theochem.tuwien.ac.at
Subject: [Wien] BAND GAP USING LB94

Dear Wien2k users,I want to calculate band gap using LB94 potential. As it
is a potential only and no energy expression available for this potential.
So would you please tell me what is the procedure to use this potential
after PBE calculation ??

with regards,
Subrata Jana


_______________________________________________
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html

Reply via email to