That direction wrong error probably means their is a problem with your case.in5(c) file with either parameter npy not being greater than 1 or noorth1 (refer to section 8.14.3 Input for case.in5 in the WIEN2k usersguide).

On 3/6/2019 2:30 AM, Santanu Pathak wrote:
I am calculating the electronic structure of oxide material. There's no error in the scf run and DOS, band structure, optical properties are being studied. But after following all the steps for Electron Density plot, *a message 'DIR WRONG'* is coming in *x lapw5* as below.

image.png
Therefore electron density plot is not formed as shown below.
image.png

How can this problem be solved? Kindly let me know if any further detail is needed about the scf run or structure for solving the problem. Thank you.
/
/
/Best Regards,
/
/
Santanu Pathak/
/Senior Research Fellow/
/Variable Energy Cyclotron Centre/
/1/AF Bidhan Nagar, Kolkata-700064, India
/
/Phone no.: 033-2318-4460 / ///09163419475//
/
/

_______________________________________________
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
_______________________________________________
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html

Reply via email to