Actually, it is strongly recommended to use the previously converged
density (init -prec 2 -nodstart), except when RMTs were .gt. 2.3 bohr.
In this case the RMTs get reduced to 2.3 and the old clmsum files cannot
be used.
I'll probably modify init_lapw such that the reduction of the RMTs can
be avoided (the HDLOs usually do a good job in reducing a possible
linearization error).
Am 06.05.2024 um 17:02 schrieb Mikhail Nestoklon via Wien:
Dear Pranjal,
it was discussed in mailing list, -prec 2/3 may change some settings
which does not allow to reuse previous calculations.
Sincerely,
M.
Dear All,
Hello.
Version 23.2
Suppose if I do a calculation with prec 1 and then I save
everything that I need (save_lapw). On the same structure I
would like to do the same calculations BUT this time with prec 2.
In this case, when I run SCF, do I need to delete the old scf
files or can I keep continuing from the old ones (in w2web when
you click on Run SCF, they give you the option to save/delete or
continue from the previous data)?
I would like to kindly confirm what is the correct way to do (to
optimise time).
Kindly let me know.
Thank you.
With warm regards,
Pranjal
Aquest missatge, i els fitxers adjunts que hi pugui haver, pot
contenir informació confidencial o protegida legalment i
s’adreça exclusivament a la persona o entitat destinatària. Si
no consteu com a destinatari final o no teniu l’encàrrec de
rebre’l, no esteu autoritzat a llegir-lo, retenir-lo,
modificar-lo, distribuir-lo, copiar-lo ni a revelar-ne el
contingut. Si l’heu rebut per error, informeu-ne el remitent i
elimineu del sistema tant el missatge com els fitxers adjunts
que hi pugui haver.
Este mensaje, y los ficheros adjuntos que pueda incluir, puede
contener información confidencial o legalmente protegida y está
exclusivamente dirigido a la persona o entidad destinataria. Si
usted no consta como destinatario final ni es la persona
encargada de recibirlo, no está autorizado a leerlo, retenerlo,
modificarlo, distribuirlo o copiarlo, ni a revelar su contenido.
Si lo ha recibido por error, informe de ello al remitente y
elimine del sistema tanto el mensaje como los ficheros adjuntos
que pueda contener.
This email message and any attachments it carries may contain
confidential or legally protected material and are intended
solely for the individual or organization to whom they are
addressed. If you are not the intended recipient of this message
or the person responsible for processing it, then you are not
authorized to read, save, modify, send, copy or disclose any
part of it. If you have received the message by mistake, please
inform the sender of this and eliminate the message and any
attachments it carries from your account.
_______________________________________________
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
</compose?To=Wien@zeus.theochem.tuwien.ac.at>
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
<http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien>
SEARCH the MAILING-LIST at:
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
<http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html>
_______________________________________________
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
--
--------------------------------------------------------------------------
Peter BLAHA, Inst.f. Materials Chemistry, TU Vienna, A-1060 Vienna
Phone: +43-1-58801-165300
Email: peter.bl...@tuwien.ac.at WIEN2k: http://www.wien2k.at
WWW: http://www.imc.tuwien.ac.at
-------------------------------------------------------------------------
_______________________________________________
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html