I'm not quite sure I understand what you did.

You are always using   mBJ  (for VX), but how do you mix in LDA or PBE ?

By default we use LDA for VC, (and anything for EX and EC, since this is not important).

Usually, the choice of VC has only a small effect (as compared to VX).

Please show the 2 lines in case.in0


Am 10.05.2024 um 15:56 schrieb Yakup Boran:
Dear Wien2K users,
I am running a calculation for a Bi-containing compound with a tetragonal structure type. I used LDA with mBJ, and then, due to the heavy Bi atom, I did the SOC calculation. The calculated band gap energy with SOC is smaller than without SOC. I checked the literature, and the band gap decrease is common for SOC calculation. However, if I use PBE-GGA with mBJ (instead of LDA with mBJ), the band gap energy with SOC is greater than without SOC, which is contrary to the literature.

 Is it possible that I get a band gap decrease with LDA while I get a band gap increase with PBE-GGA when the SOC effect is taken into consideration?

Any response will be appreciated. 

Best Regards

Yakup Bran

_______________________________________________
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html

--
-----------------------------------------------------------------------
Peter Blaha,  Inst. f. Materials Chemistry, TU Vienna, A-1060 Vienna
Phone: +43-158801165300
Email: peter.bl...@tuwien.ac.at
WWW:   http://www.imc.tuwien.ac.at      WIEN2k: http://www.wien2k.at
-------------------------------------------------------------------------

_______________________________________________
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html

Reply via email to