I'm not quite sure I understand what you did.
You are always using mBJ (for VX), but how do you mix in LDA or PBE ?
By default we use LDA for VC, (and anything for EX and EC, since this is
not important).
Usually, the choice of VC has only a small effect (as compared to VX).
Please show the 2 lines in case.in0
Am 10.05.2024 um 15:56 schrieb Yakup Boran:
Dear Wien2K users,
I am running a calculation for a Bi-containing compound with a
tetragonal structure type. I used LDA with mBJ, and then, due to the
heavy Bi atom, I did the SOC calculation. The calculated band gap
energy with SOC is smaller than without SOC. I checked the literature,
and the band gap decrease is common for SOC calculation. However, if I
use PBE-GGA with mBJ (instead of LDA with mBJ), the band gap energy
with SOC is greater than without SOC, which is contrary to the
literature.
Is it possible that I get a band gap decrease with LDA while I get a
band gap increase with PBE-GGA when the SOC effect is taken into
consideration?
Any response will be appreciated.
Best Regards
Yakup Bran
_______________________________________________
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html
--
-----------------------------------------------------------------------
Peter Blaha, Inst. f. Materials Chemistry, TU Vienna, A-1060 Vienna
Phone: +43-158801165300
Email: peter.bl...@tuwien.ac.at
WWW: http://www.imc.tuwien.ac.at WIEN2k: http://www.wien2k.at
-------------------------------------------------------------------------
_______________________________________________
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html