Ed Brannin wrote : > On 8/7/07, Greg Donhardt <greg.donha...@flinders.edu.au> wrote: >> When I go to a venue, I get 4 vic >> service windows appear (one for each camera), however in my Vic consumer >> window I can only see 3 of my 4 streams. Ironically it us the camera >> designated as source 4 that is not appearing. It is not appearing in the >> 4 >> service windows either. I have confirmed that the camera is working >> locally >> at the computer so I believe it to be an AG related issue. > > This is a known issue in AG3.1 -- or at least, we've known about it at > RIT, and I hope we made it known to UCL... if not, I'm embarrassed > and glad you need the 4th camera more than we needed ours. > > In short, the VIC bundled with AG3.1b1 seems to see only the first 3 > video sources, even when we click on the "Sources" menu.
The vic that came with AG3.1beta only scanned for a max of 4 devices ( I suspect the first device that gets scanned is the Microsoft WDM VfW wrapper). I can see that a fix was checked-in to the UCL SVN repository last month, which makes vic scan a max of 20 capture devices, see: http://mediatools.cs.ucl.ac.uk/nets/mmedia/changeset/4078 Cheers, Doug