On 8/7/07, Greg Donhardt <greg.donha...@flinders.edu.au> wrote: > When I go to a venue, I get 4 vic > service windows appear (one for each camera), however in my Vic consumer > window I can only see 3 of my 4 streams. Ironically it us the camera > designated as source 4 that is not appearing. It is not appearing in the 4 > service windows either. I have confirmed that the camera is working locally > at the computer so I believe it to be an AG related issue.
This is a known issue in AG3.1 -- or at least, we've known about it at RIT, and I hope we made it known to UCL... if not, I'm embarrassed and glad you need the 4th camera more than we needed ours. In short, the VIC bundled with AG3.1b1 seems to see only the first 3 video sources, even when we click on the "Sources" menu. Anyway, for now I suggest you replace your c:\Documents and Settings\YourUserName\Application Data\AccessGrid3\NodeServices\VideoProducerService folder with the one from AG3.0.2. Hope This Helps, -- -Ed Brannin edbran...@gmail.com cell: 585-261-0279 -- -Ed Brannin edbran...@gmail.com cell: 585-261-0279