Yes, the results were the same when launching these from the command prompt window. I have since launched from a batch file with complete success. After a little more exploring I will polish the batch file so as to be a little more flexible.
Thanks to all who responded. This will enhance our use of the Access Grid. Bob W. 243-2857 -----Original Message----- From: gurcharan khanna [mailto:gkha...@dartmouth.edu] Sent: Monday, November 07, 2005 11:28 AM To: Wachtel, Robert L Cc: Nagykaldi, Zsolt F. (HSC); ag-t...@mcs.anl.gov Subject: Re: [AG-TECH] Starting VIC & RAT manually bob, did you try both versions of vic in the two differenct directories with the same result? -gurcharan Wachtel, Robert L wrote: > This has gotten us part way there. > > > > Actually there are two separate videoservice directories > videoproducerservice and videoconsumerservice. It does not seem to > matter which is run to launch the VIC to participate in the session. > > > > I am able to launch RAT and have good bidirectional audio with the > group. The VIC however seems to not recognize the incoming video from > the group. I can send video from my Logitec USB camera but cannot receive. > > > > Further thoughts would be appreciated. > > > > Bob W. > > 243-2857 > > ------------------------------------------------------------------------ > > *From:* Nagykaldi, Zsolt F. (HSC) [mailto:zsolt-nagyka...@ouhsc.edu] > *Sent:* Monday, November 07, 2005 9:29 AM > *To:* Wachtel, Robert L; ag-t...@mcs.anl.gov > *Subject:* RE: [AG-TECH] Starting VIC & RAT manually > > > > > > Go to C:\Documents and Settings\<your username>\Application > Data\AccessGrid\local_services\AudioService > > > > rat.exe -t 127 233.14.223.22/57014 > > > > Then cd to C:\Documents and Settings\<your username>\Application > Data\AccessGrid\local_services\VideoService > > > > vic.exe -t 127 233.14.223.22/57016 > > > > > > I am not sure inSORS allows you to jump on board like that, without > using their interface. If this works, let me know. > > > > Zsolt > > > > _ _ _ > > > > Zsolt Nagykaldi, PhD > > Research Associate, Clinical IT Specialist > > University Of Oklahoma Health Sciences Center > > Department Of Family And Preventive Medicine > > Oklahoma Center For Family Medicine Research > > > > 900 NE 10th Street > > Oklahoma City, OK 73104 > > Phone: (405) 271-8000 Ext.:1-32212 > > Fax: (405) 271-1682 > > > > ------------------------------------------------------------------------ > > *From:* owner-ag-t...@mcs.anl.gov on behalf of Wachtel, Robert L > *Sent:* Mon 11/7/2005 9:45 AM > *To:* ag-t...@mcs.anl.gov > *Subject:* [AG-TECH] Starting VIC & RAT manually > > I am anticipating the need to have some AGTk2.4 users join sessions > initiated through our inSORS venue server to any one of four venues we > host at The University of Montana. I know that I have seen references on > this list regarding starting the VIC & RAT manually to join an existing > session but I have not found sufficient detail to allow me to > successfully connect to one of these sessions. > > > > Environment: > > Dell Optiplex GX280 > > Windows XP SP2 > > AGTk 2.4 fully functional via Venue Client > > > > Session being configured by inSORS venue server: > > IP 233.14.223.22 Video port 57016 Audio port 57014 > > > > Please provide exact syntax for command entry. > > > > Thanks in advance, > > Bob Wachtel > > Director, Presentation & Technology Services > > The University of Montana > > Missoula, MT 59812 > > > > phone: 406-243-2857 > > cell phone 406-396-1192 > > fax: 406-243-2689 > > > -- --- Gurcharan S. Khanna, Ph.D. Director of Academic Research Computing Rochester Institute of Technology 1 Lomb Memorial Drive Rochester, New York 14623-5603 Phone: 585-475-7504 ~ Fax: 585-475-6886 Email: gurcharan.kha...@rit.edu Http: www.rit.edu/~gskpop