The one I can remember off the top of my head is the Fstypes option, it is no longer 
supported and if it is in the OPT file, it will cause Dr Watson.  I believe we had 
another non supported option cause the same problem, but I can't remember it.  Sorry.  
I would review any OPT file you are going to copy and question any options that seam 
out of place. That's how we found ours.

-----Original Message-----
From: LeBlanc, Patricia [mailto:[EMAIL PROTECTED]]
Sent: Thursday, April 12, 2001 2:21 PM
To: [EMAIL PROTECTED]
Subject: Re: Dr. Watson in NT after installing TSM4.1


What are the options you are talking about that are no longer supported??

> -----Original Message-----
> From: Miller, Ryan [SMTP:[EMAIL PROTECTED]]
> Sent: Thursday, April 12, 2001 3:13 PM
> To:   [EMAIL PROTECTED]
> Subject:      Re: Dr. Watson in NT after installing TSM4.1
>
> Did you use the original OPT file?  If so, there are some options that can
> cause Dr Watson errors.  They are options that are no longer supported by
> the newer client, we have experienced this issue also and found this
> cause.
>
> -----Original Message-----
> From: Gottfried Scheckenbach
> [mailto:[EMAIL PROTECTED]]
> Sent: Thursday, April 12, 2001 11:24 AM
> To: [EMAIL PROTECTED]
> Subject: Re: Dr. Watson in NT after installing TSM4.1
>
>
> Because there where no answers:
>
> Today I had the same problem - after upgrading a old ADSM 3.1 to TSM 4.1
> installation on NT with SP 3. Just after installation of SP 6 all went
> fine.
>
> Regards,
> Gottfried
>
>
> Shekhar Dhotre wrote:
> >
> > Hi all ,
> >
> > I   installed TSM server 4.1  on WINNT 4.0 service pack 4 , RAM 256 MB
> > whenever i  open configuration wizard   to configure any of the
> parameters in
> > TSM
> > DR. WATSON  shows his face ..  what should i check to correct this
> problem ..
> >
> > Thanks
> > shekhar

Reply via email to