Dear (I)*SM-ers, a defect 3590 extended length cartridge was replaces by IBM. When I try to label this cartridge for our 3494 library with "LABEL libvolume lib3494 010251 checkin=scratch devtype=3590" I get the following errors:
07/11/02 17:23:48 ANR2017I Administrator SYSA issued command: LABEL libvolume lib3494 010251 checkin=scratch devtype=3590 07/11/02 17:23:48 ANR0984I Process 16 for LABEL LIBVOLUME started in the BACKGROUND at 17:23:48. 07/11/02 17:23:48 ANR8799I LABEL LIBVOLUME: Operation for library LIB3494 started as process 16. 07/11/02 17:23:48 ANR0609I LABEL LIBVOLUME started as process 16. 07/11/02 17:31:44 ANR8302E I/O error on drive DRIVE2 (/dev/rmt2) (OP=WEOF, Error Number=110, CC=0, KEY=03, ASC=09, ASCQ=00, SENSE=F0.00.03.00.00.00.04.58.00.00.00.00.09.00.FE.0A.3- 1.18.50.00.00.03.01.31.08.0A.42.48.22.80.10.00.10.35.42- .12.01.33.12.00.80.33.54.80.06.00.00.00.00.04.00.00.00.- 00.00.00.00.80.00.00.00.00.00.00.01.00.00.00.3C.00.20.0- 0.32.32.45.20.20.20.20.00.A0.00.4B.F0.F1.F0.F2.F5.F1.00- .00.00.00.00.00.00, Description=An undetermined error has occurred). Refer to Appendix D in the 'Messages' manual for recommended action. 07/11/02 17:31:44 ANR8806E Could not write volume label 010251 on the tape in library LIB3494. 07/11/02 17:34:09 ANR8802E LABEL LIBVOLUME process 16 for library LIB3494 failed. 07/11/02 17:34:09 ANR0985I Process 16 for LABEL LIBVOLUME running in the BACKGROUND completed with completion state FAILURE at 17:34:09. KEY=03 means: medium error ASC=09 and ASCQ=00 mean: "Track following error". Does this mean that the new cartridge is defect as well? Kind regards Thomas Rupp Vorarlberger Illwerke AG MAIL: [EMAIL PROTECTED] TEL: ++43/5574/4991-251 FAX: ++43/5574/4991-820-8251 ------------------------------------------------------------------------------------------ Dieses eMail wurde auf Viren geprueft. Vorarlberger Illwerke AG ------------------------------------------------------------------------------------------