Thomas, If you read along the line of SENSE data you will see FE.OA.31.18 .xx.xx.xx.
The FE is the FID (FRU identification number) 3118 is the first fault sympton code see the 3590 Maintenance manual ( SA37-0301-04 ). IBM Hardware support informed us that codes such as FE 3118 FE 3117 FE 301C FE 3542 FE 3A5B were errors writing the servo-track along the tape. You will need a new tape - send this one back under it's warranty. We experienced this mainly with the early use of 256 track 3590-E1A drives ( along with early microcode ). We still see this occasionally. HTH Ian Smith ------------------------------------------------------------------- Ian Smith Oxford University Computing Services, Oxford, UK. ------------------------------------------------------------------- ~>MIME-Version: 1.0 ~>Date: Fri, 12 Jul 2002 15:32:31 +0200 ~>From: "Rupp Thomas (Illwerke)" <[EMAIL PROTECTED]> ~>Subject: Label new 3590 cartridge ~>To: [EMAIL PROTECTED] ~> ~>Dear (I)*SM-ers, ~> ~>a defect 3590 extended length cartridge was replaces by IBM. ~>When I try to label this cartridge for our 3494 library with ~>"LABEL libvolume lib3494 010251 checkin=scratch devtype=3590" I get the ~>following errors: ~> ~>07/11/02 17:23:48 ANR2017I Administrator SYSA issued command: LABEL ~>libvolume lib3494 010251 checkin=scratch devtype=3590 ~>07/11/02 17:23:48 ANR0984I Process 16 for LABEL LIBVOLUME started in the ~>BACKGROUND at 17:23:48. ~>07/11/02 17:23:48 ANR8799I LABEL LIBVOLUME: Operation for library LIB3494 ~>started as process 16. ~>07/11/02 17:23:48 ANR0609I LABEL LIBVOLUME started as process 16. ~>07/11/02 17:31:44 ANR8302E I/O error on drive DRIVE2 (/dev/rmt2) (OP=WEOF, ~>Error Number=110, CC=0, KEY=03, ASC=09, ASCQ=00, ~>SENSE=F0.00.03.00.00.00.04.58.00.00.00.00.09.00.FE.0A.3- ~>1.18.50.00.00.03.01.31.08.0A.42.48.22.80.10.00.10.35.42- ~>.12.01.33.12.00.80.33.54.80.06.00.00.00.00.04.00.00.00.- ~>00.00.00.00.80.00.00.00.00.00.00.01.00.00.00.3C.00.20.0- ~>0.32.32.45.20.20.20.20.00.A0.00.4B.F0.F1.F0.F2.F5.F1.00- ~>.00.00.00.00.00.00, Description=An undetermined error has ~>occurred). Refer to Appendix D in the 'Messages' manual for recommended ~>action. ~>07/11/02 17:31:44 ANR8806E Could not write volume label 010251 on the tape ~>in library LIB3494. ~>07/11/02 17:34:09 ANR8802E LABEL LIBVOLUME process 16 for library LIB3494 ~>failed. ~>07/11/02 17:34:09 ANR0985I Process 16 for LABEL LIBVOLUME running in the ~>BACKGROUND completed with completion state FAILURE at 17:34:09. ~> ~>KEY=03 means: medium error ~>ASC=09 and ASCQ=00 mean: "Track following error". ~> ~>Does this mean that the new cartridge is defect as well? ~> ~>Kind regards ~>Thomas Rupp ~>Vorarlberger Illwerke AG ~>MAIL: [EMAIL PROTECTED] ~>TEL: ++43/5574/4991-251 ~>FAX: ++43/5574/4991-820-8251 ~> ~> ~> ~>------------------------------------------------------------------------------ ------------ ~>Dieses eMail wurde auf Viren geprueft. ~> ~>Vorarlberger Illwerke AG ~>------------------------------------------------------------------------------ ------------