It's either corrupt or actually blank, meaning that TSM has written data on it, but the hardware didnt actually write the data (common when using an incorrect FC driver for example).
The "q volume" command only gathers data from the database, thus not proving that the cartridge actually contains data. I'm guessing you didnt do checkl=barcode when auditing the library. That means that TSM actually tried reading the data on the cartridge, but failed. Best Regards Daniel Sparrman Daniel Sparrman Exist i Stockholm AB Växel: 08-754 98 00 Fax: 08-754 97 30 [email protected] http://www.existgruppen.se Posthusgatan 1 761 30 NORRTÄLJE -----"ADSM: Dist Stor Manager" <[email protected]> skrev: ----- Till: [email protected] Från: Mehdi Salehi <[email protected]> Sänt av: "ADSM: Dist Stor Manager" <[email protected]> Datum: 08/14/2011 08:15 Ärende: [ADSM-L] The volume has data but I get this: ANR8941W Hi, After audit library: ANR8941W The volume from slot-element 4098 in drive LTODRIVE0 (/dev/rmt0) in library LIB3310 is blank. But the volume is not only labeled, but has data: Volume Name Storage Device Estimated Pct Volume Pool Name Class Name Capacity Util Status ------------------------ ----------- ---------- --------- ----- -------- TS0045 POOL3310 CLASS3310 919,886.1 92.5 Full Does it mean the volumes is corrupted? Thanks.