We've had problems with the RF screwing up ethernet, but if the there was
any interference the other direction, nobody ever told us about it. Ferrite
beads on everything mostly fixed that... on that site, we had everything up
top, with only DC going running down to the ground.  Last fall we moved the
routers into a metal box (the old one was fiberglass). Somebody here
recommended terminating the shielded cat5's as close as possible to where
they enter the box, and running unshielded patch cables from there, so I
mounted a PRM24 full of MTC surge suppressors at the very bottom. I don't
think we've had any problems since doing that.

On Thu, Feb 28, 2019 at 3:42 PM Josh Luthman <[email protected]>
wrote:

> This RF interference, I'm expecting you've proved it's already ethernet.
> What is it causing issues with, exactly (besides "the repeater").  Is it RF
> communication between the handsets and tower or communication between their
> equipment at the tower?
>
> If it were me I'd start with a Powerbox Pro, Edgewhatever, Netonix, etc
> and do super short cat5 from the radio to the (choice of switch).  Running
> DC/cat5 for power but NOT ethernet and then a fiber if you need it to the
> ground.  Conduit may also work, that's a lot of shielding between your
> ethernet and their stuff.
>
> Josh Luthman
> Office: 937-552-2340
> Direct: 937-552-2343
> 1100 Wayne St
> Suite 1337
> Troy, OH 45373
>
>
> On Thu, Feb 28, 2019 at 3:46 PM Craig House <[email protected]>
> wrote:
>
>>
>> >
>> > I think I’ve posted this question on here before but I want to try
>> again. We have multiple water towers where we have various types of
>> equipment a mix of Mimosa cambium and ubiquity products. It seems that on
>> many of these water towers our cat five power over ethernet creates RF
>> interference for the repeater. In one instance we were able to install
>> magnets that clamped around the cable which did help enough they stopped
>> complaining. In other cases we’ve attempted to move our equipment from the
>> top of the water tower down to the catwalk to create some distance and
>> installed the ferrite beads with little success at all. I’m tired of
>> playing with ideas that might or might not work. Can someone give me advice
>> that will solve this problem once and for all. I understand that grounding
>> the CAT5 might help I’ve also been told that putting our wires inside of
>> conduit might help or shortening the wires might help. I don’t want anymore
>> might help I would like someone who has actually done this to be able to
>> give me some advice
>> >
>> > Sent from my iPhone
>> --
>> AF mailing list
>> [email protected]
>> http://af.afmug.com/mailman/listinfo/af_af.afmug.com
>>
> --
> AF mailing list
> [email protected]
> http://af.afmug.com/mailman/listinfo/af_af.afmug.com
>
-- 
AF mailing list
[email protected]
http://af.afmug.com/mailman/listinfo/af_af.afmug.com