Anyone have much experience with molded concealment panels? On a particular 
structure, the tower owner added panels in front of our equipment to great 
detriment.. Looking for an alternative product that won’t crap on our parade.

 

We performed testing today at 5.8 Ghz.. Here is a table of before and after 
signals for 5 customers we took measurements from

 

Before / After / Delta

HC -56.0 / -57.4 = 1.4

RO -63.7 / -65.2 = 1.5

WB -58.7 / -60.5 = 1.8

SF -59.9 / -61.8 = 1.9

GG -60.7 / -62.5 = 1.8

 

As you can see the average attenuation of the panel was measured to be -1.68dB 
(a 20% reduction in signal level).. This is similar to the vendor provided 
attenuation number of 1.31dB for straight on and -2.66dB for 45 degree



45 degree angle:





 

-Peter

Reply via email to