Probe tab? Really doubt it. Josh Luthman Office: 937-552-2340 Direct: 937-552-2343 1100 Wayne St Suite 1337 Troy, OH 45373 On Aug 5, 2015 12:24 PM, "That One Guy /sarcasm" <[email protected]> wrote:
> We did the 5.6 beta and went through the probe fixes some time back. > Haven't added any probes. > > These situations require liberal applications of swear words and liquor to > troubleshoot when home at night and would rather be doing something other > than troubleshooting. > > I have an open ticket with them, they were looking at it, I saw in the log > they poked some ubnt probes. > > I see in the billing server logs they were looking at time. > > Would rrd and time issue affect the probes tab updates > On Aug 5, 2015 8:57 AM, "Josh Luthman" <[email protected]> > wrote: > >> If you have one bad OID for a price none of them work. Removing the bad >> one makes the probes work instantly. >> >> Status check isn't effected by this. >> >> Josh Luthman >> Office: 937-552-2340 >> Direct: 937-552-2343 >> 1100 Wayne St >> Suite 1337 >> Troy, OH 45373 >> On Aug 5, 2015 9:46 AM, "Jason Pond" <[email protected]> wrote: >> >>> I had this happen last week when I started upgrading my ubnt network to >>> 5.6.2 it is the result of a bad SNMP probe causing all SNMP to stop >>> functioning from the powercode server. I opened a ticket with powercode >>> and they were able to resolve it. >>> >>> If you made any changes to the monitoring you might want to try to >>> remove bad probes. Probes that were working on 5.5.x are not the same for >>> 5.6.x. Once the bad probes were removed it took about 3 hours for things >>> to really start populating graphs again. >>> >>> Sincerely, >>> >>> Jason Pond >>> >>> On Tue, Aug 4, 2015 at 10:53 PM, That One Guy /sarcasm < >>> [email protected]> wrote: >>> >>>> Rebooted this evening, pushed the pending update this morning hoping it >>>> was that (two revisions pending) no joy.Im at 20gb of 91gb space on the >>>> VHD. This is a massive virtual server terabyte raid 10 array powercode >>>> datastore 16 core 64gb ram host. Only thing on it is powercode and two >>>> lightly hit DNS servers behind a firewall that shows little traffic, so not >>>> likely an external issue >>>> >>>> On Tue, Aug 4, 2015 at 11:48 PM, Josh Luthman < >>>> [email protected]> wrote: >>>> >>>>> Disk full? Are you monitoring the servers health? >>>>> >>>>> Might want to try rebooting the billing server, do a snapshot before >>>>> though. >>>>> >>>>> Josh Luthman >>>>> Office: 937-552-2340 >>>>> Direct: 937-552-2343 >>>>> 1100 Wayne St >>>>> Suite 1337 >>>>> Troy, OH 45373 >>>>> On Aug 5, 2015 12:45 AM, "That One Guy /sarcasm" < >>>>> [email protected]> wrote: >>>>> >>>>>> bandwidth gathering seems to be functional, probes are busted, about >>>>>> every tenth click on reprobe gives me a green box, but it never populates >>>>>> the probes. I rebooted the bmu when the mirror was still present and >>>>>> probes >>>>>> worked during the resync, but failed again at some point, subsequent >>>>>> reboots would not replicate the temporary functionality. >>>>>> >>>>>> I cannot find any devices, customer or infrastructure that are >>>>>> working, so it seems the entire module is failing, not just hanging at >>>>>> some >>>>>> point in the polling as best I can tell >>>>>> >>>>>> On Tue, Aug 4, 2015 at 11:35 PM, Josh Luthman < >>>>>> [email protected]> wrote: >>>>>> >>>>>>> So probes are what's busted? What about bandwidth collection? >>>>>>> >>>>>>> Josh Luthman >>>>>>> Office: 937-552-2340 >>>>>>> Direct: 937-552-2343 >>>>>>> 1100 Wayne St >>>>>>> Suite 1337 >>>>>>> Troy, OH 45373 >>>>>>> On Aug 5, 2015 12:31 AM, "That One Guy /sarcasm" < >>>>>>> [email protected]> wrote: >>>>>>> >>>>>>>> anybody using powercode and your monitoring is dead? Hopefully its >>>>>>>> just us and not systemic. Apparently they tested and they can kick >>>>>>>> probes >>>>>>>> off on the back end, its just not logging. real time tools work, so >>>>>>>> its not >>>>>>>> a communication issue, we didnt make any system changes near the >>>>>>>> failure. >>>>>>>> The entire network monitoring component seems to be croaked. Ive >>>>>>>> removed mirrors, minimized down to a single bmu, synchronized, >>>>>>>> restarted >>>>>>>> BMUs, restarted the billing server, cussed and got drunk, nothing >>>>>>>> seems to >>>>>>>> work. >>>>>>>> I cant say Im all that excited with responsiveness at bertram since >>>>>>>> the coup so Im reaching out to the community hoping somebody has this >>>>>>>> happen occasionally and its something like running some archaic linux >>>>>>>> command and burning sage. >>>>>>>> Our customer facing staff is bright as a brick when it comes to >>>>>>>> using the statuses as it is and this is going to be a disaster, no >>>>>>>> matter >>>>>>>> how much i try to show them. We have 3/4 technical staff tied up all >>>>>>>> day >>>>>>>> tomorrow migrating an office domain so that coupled with the inevitable >>>>>>>> hangover is going to make this situation salty >>>>>>>> >>>>>>>> -- >>>>>>>> If you only see yourself as part of the team but you don't see your >>>>>>>> team as part of yourself you have already failed as part of the team. >>>>>>>> >>>>>>> >>>>>> >>>>>> >>>>>> -- >>>>>> If you only see yourself as part of the team but you don't see your >>>>>> team as part of yourself you have already failed as part of the team. >>>>>> >>>>> >>>> >>>> >>>> -- >>>> If you only see yourself as part of the team but you don't see your >>>> team as part of yourself you have already failed as part of the team. >>>> >>> >>>