I saw an analysis done by DCI on a public safety tower and frankly was so ridiculous for adding three 3.65 Sectors on at 45 ft mark of 300 tower. I understand when wind loading can be an issue on some towers but this was a tower with 8 ft base and guyed... One 6 ft dish at 80 ft mark with VHF and UHF antennas near the top. On Sep 23, 2015 8:46 PM, "Faisal Imtiaz" <[email protected]> wrote:
> How about asking the Tower owner who was the last engineer who did the > structural on that tower.. and contacting them.. > If they are cooperative, it could be the least expensive option than going > to someone new.. > > Just my 2 cents. > > Regards. > > Faisal Imtiaz > Snappy Internet & Telecom > 7266 SW 48 Street > Miami, FL 33155 > Tel: 305 663 5518 x 232 > > Help-desk: (305)663-5518 Option 2 or Email: [email protected] > > ------------------------------ > > *From: *"Darin Steffl" <[email protected]> > *To: *[email protected], "[email protected]" <[email protected]> > *Sent: *Wednesday, September 23, 2015 9:21:23 PM > *Subject: *[WISPA Members] Tower Structural Analysis Vendors > > Hey guys, > One of our new tower site owners is requiring us to have a structural > analysis done even though we have a very small load on the tower. > > Are there any reasonably priced vendors you recommend to perform the > analysis that don't cost a fortune? > > Thank you > > -- > Darin Steffl > Minnesota WiFi > www.mnwifi.com > 507-634-WiFi > <http://www.facebook.com/minnesotawifi> Like us on Facebook > <http://www.facebook.com/minnesotawifi> > > _______________________________________________ > Members mailing list > [email protected] > http://lists.wispa.org/mailman/listinfo/members > >