No.....nor does rebooting the router. I have several SFP's in at least
3 CCR's with the same anomaly. Today just happens to be the first time
I noticed it, but I assume it's been like that for a little while.
On 11/18/2015 12:03 PM, Josh Luthman wrote:
You have an awesome noise floor in that light tunnel...
Did restarting the interface fix the power readout?
Josh Luthman
Office: 937-552-2340
Direct: 937-552-2343
1100 Wayne St
Suite 1337
Troy, OH 45373
On Wed, Nov 18, 2015 at 12:01 PM, Adam Moffett <[email protected]
<mailto:[email protected]>> wrote:
I have a few CCR's on 3.32.3 with the same model SFP in all of
them. They're all showing screwball numbers for tx and rx power.
With ROS 6.29, same model SFP, and same model CCR I get realistic
numbers. I'm not sure if it's only some kind of a display
artifact or a symptom of something worse, but this morning one of
these SFP's stopped passing traffic and it started up again after
I disabled and re-enabled it.
I may drop back to 6.29 as precaution. I don't suppose anybody
else has seen this on 6.32.3?