I wish a GUI glitch was the worst of my problems.

On 12/4/2015 12:57 PM, That One Guy /sarcasm wrote:
The more We are using EPMP the more i wish the radios had a face so i could punch it in the face

On Thu, Dec 3, 2015 at 7:35 PM, George Skorup <geo...@cbcast.com <mailto:geo...@cbcast.com>> wrote:

    Yes. You cannot have single quotes in the device name. I tried
    that once and the radio acted really stupid. None of the config
    would display. For example, I changed it from "Bob's House" to
    "Bobs House" and it was sane again.

    Almost the same thing on Canopy, just a little bit smarter about
    it. It won't even let you put a ' in the SNMP site name field. It
    just reverts back to the No Site Name default.

    On 12/3/2015 7:29 PM, Mike Hammett wrote:
    I think it was related to a single quote ' in some of the fields
    of the config. I dumped the config, edited them out and now it
    seems to be fine.



    -----
    Mike Hammett
    Intelligent Computing Solutions
    http://www.ics-il.com

    
<https://www.facebook.com/ICSIL><https://plus.google.com/+IntelligentComputingSolutionsDeKalb><https://www.linkedin.com/company/intelligent-computing-solutions><https://twitter.com/ICSIL>

    Midwest Internet Exchange
    http://www.midwest-ix.com

    
<https://www.facebook.com/mdwestix><https://www.linkedin.com/company/midwest-internet-exchange><https://twitter.com/mdwestix>
    ------------------------------------------------------------------------
    *From: *"Josh Luthman" <j...@imaginenetworksllc.com>
    <mailto:j...@imaginenetworksllc.com>
    *To: *af@afmug.com <mailto:af@afmug.com>
    *Sent: *Thursday, December 3, 2015 6:44:54 PM
    *Subject: *Re: [AFMUG] Force 110

    Never had a problem, but keep in mind I use one PC to update from
    shipped firmware to latest and then slap on a template.

    Then I use the laptop in the truck to do everything else on site.


    Josh Luthman
    Office: 937-552-2340 <tel:937-552-2340>
    Direct: 937-552-2343 <tel:937-552-2343>
    1100 Wayne St
    Suite 1337
    Troy, OH 45373

    On Thu, Dec 3, 2015 at 7:33 PM, Mathew Howard
    <mhoward...@gmail.com <mailto:mhoward...@gmail.com>> wrote:

        I saw something like that happen, but it went back to normal
        after I reloaded the interface... or maybe I had to reboot
        it, I don't remember for sure.

        On Thu, Dec 3, 2015 at 6:31 PM, Mike Hammett
        <af...@ics-il.net <mailto:af...@ics-il.net>> wrote:

            Have any of you seen where most of a Force 110's setting
            fields are blank when you login and when you go to save
            it after entering everything, it wants to reboot to the
            192.168.0.2 address? That's clearly not what I have
            entered, but that's what it wants to use.



            -----
            Mike Hammett
            Intelligent Computing Solutions
            http://www.ics-il.com

            
<https://www.facebook.com/ICSIL><https://plus.google.com/+IntelligentComputingSolutionsDeKalb><https://www.linkedin.com/company/intelligent-computing-solutions><https://twitter.com/ICSIL>

            Midwest Internet Exchange
            http://www.midwest-ix.com

            
<https://www.facebook.com/mdwestix><https://www.linkedin.com/company/midwest-internet-exchange><https://twitter.com/mdwestix>








--
If you only see yourself as part of the team but you don't see your team as part of yourself you have already failed as part of the team.

Reply via email to