We have two 11GHz links on the same freqs. One V and one H pol. These are dual 
links, 2 - 40Mhz channels. The radios are Dragonwave, one Quantum and the other 
a Horizion Duo.

We had to replace the IDU of the Quantum with a DUO and put the link into DUO 
compatibility mode. 

After replacing the IDU, we started having issues on the other link. The RX 
levels of one freq dropped by 9dBm, the equalizer stress jumped to 150 (should 
be under 100), and the link would only run at 32QAM.

This morning I moved the IDU up 1 RU (it was sitting directly onto of the other 
IDU) and tightened the coax by 3/4 of a turn. Gained 9dB, lowered equalizer 
stress by 50, and now running at 256QAM.

I check the IF freqs and they were separated by 200MHz.

I’m curious, does anyone have an idea why this happened?

Reply via email to