I know sitepro1.com had them as well as rothenslhan I think. That looks
last one is not right but I can't remember the name.

On Thu, Feb 18, 2016, 11:10 AM Sam Lambie <[email protected]> wrote:

> Lewis, got a link on the buffer tour inserts by chance?
>
>
> On Wed, Feb 17, 2016 at 5:36 PM, Lewis Bergman <[email protected]>
> wrote:
>
>> We used the buffer tour rubber inserts for 1 5/8" snap Ind. They work
>> great but you shouldn't space them farther than 2.5 feet apart.
>>
>> On Wed, Feb 17, 2016, 1:27 PM Sam Lambie <[email protected]> wrote:
>>
>>> Thanks for the input people. Most helpful!
>>>
>>> On Wed, Feb 17, 2016 at 12:13 PM, George Skorup <[email protected]>
>>> wrote:
>>>
>>>> All we use is TnB Ty-Raps MX series with the steel tooth. Just need to
>>>> be on the slightly careful side and not tighten them all to hell. If you're
>>>> really paranoid, put down some decent electrical tape over the bundle and
>>>> then the Ty-Rap over that.
>>>>
>>>> On 2/17/2016 8:23 AM, Chuck McCown wrote:
>>>>
>>>> Good point, tape is not tape is not tape.  The cheap crap you find on
>>>> sale is way different than a 3M 33+ or 88T good quality tape.  They work
>>>> when it is very cold and will stay there for  years.
>>>>
>>>> *From:* Chris Fabien <[email protected]>
>>>> *Sent:* Tuesday, February 16, 2016 6:47 PM
>>>> *To:* [email protected]
>>>> *Subject:* Re: [AFMUG] Securing lots of cable to Rohn 45
>>>>
>>>>
>>>> I would just leave it. On most small towers we use super 33 tape to
>>>> hold cat5 to leg. 6 yrs in haven't seen a problem.
>>>> On Feb 16, 2016 7:39 PM, "Sean Heskett" <[email protected]> wrote:
>>>>
>>>>> i would just leave it in place
>>>>>
>>>>> On Tue, Feb 16, 2016 at 5:06 PM, Sam Lambie < <[email protected]>
>>>>> [email protected]> wrote:
>>>>>
>>>>>> LMR 600. I might just do that...
>>>>>>
>>>>>>
>>>>>> On Tue, Feb 16, 2016 at 5:01 PM, George Skorup <[email protected]>
>>>>>> wrote:
>>>>>>
>>>>>>> What size is the FM transmission line? If it's small enough, I'd
>>>>>>> just leave it.
>>>>>>>
>>>>>>> On 2/16/2016 5:10 PM, Sam Lambie wrote:
>>>>>>>
>>>>>>> I have a 100' tower that at the moment has about 25 cables coming
>>>>>>> down and all are secured with zip ties.
>>>>>>> We have an FM transmitter that is coming down in the next couple of
>>>>>>> weeks and I will have to remove most of the zip ties to get to the Coax
>>>>>>> that is buried amongst our cables.
>>>>>>> What do you all use to secure cable down a leg of tower, now that I
>>>>>>> will basically get to start fresh?
>>>>>>>
>>>>>>>
>>>>>>>
>>>>>>> --
>>>>>>> --
>>>>>>> *Sam Lambie*
>>>>>>> Taosnet Wireless Tech.
>>>>>>> 575-758-7598 Office
>>>>>>> <http://www.newmex.com>www.Taosnet.com
>>>>>>>
>>>>>>>
>>>>>>>
>>>>>>
>>>>>>
>>>>>> --
>>>>>> --
>>>>>> *Sam Lambie*
>>>>>> Taosnet Wireless Tech.
>>>>>> 575-758-7598 Office
>>>>>> www.Taosnet.com <http://www.newmex.com>
>>>>>>
>>>>>
>>>>>
>>>>
>>>>
>>>
>>>
>>> --
>>> --
>>> *Sam Lambie*
>>> Taosnet Wireless Tech.
>>> 575-758-7598 Office
>>> www.Taosnet.com <http://www.newmex.com>
>>>
>>
>
>
> --
> --
> *Sam Lambie*
> Taosnet Wireless Tech.
> 575-758-7598 Office
> www.Taosnet.com <http://www.newmex.com>
>

Reply via email to