I had a situation like this with a Dragonwave backhaul a few years ago. Every time the OAT dropped below ~~ 25° it would drop offline. I found I could get it to "live" by wrapping the ODU in foam insulation. Helped me isolate the problem, and was able to schedule an ODU replacement.

bp
<part15sbs{at}gmail{dot}com>

On 12/19/2016 7:35 AM, Kurt Fankhauser wrote:
I have a 3.65ghz 450 AP that was running flawless for over 6 months until we got our first really cold spell last week, temps dropped to near 0 degrees a couple nights back to back and when I woke up one morning the AP was dropping offline. Logged into the Mikrotik 2011 and it showed Ethernet was flapping. (was originally going through a Sync Injector). I had an old FSK AP going through the same sync injector and wasn't showing any problems. I tried switching the ports on the sync injector, changed ports on RB2011, eliminated sync injector and used a standard Canopy SM power supply. Finally I even switched the known good Ethernet cable from the FSK AP to the 450 and the port is still flapping. Won't lock to 10-baseT either. I am thinking at this point that I am going to have to replace the AP.