Here is the background. I have a 450i SM and the Ethernet run is 302 feet
from the barn to the house. Power supply is on the far end of the Ethernet
at the barn side and the poe side of the run is probably another 50 feet.
The other end of the 302 foot is in the customers house plugged into the
router. This is the longest run we have ever done and I had some concerns
but when I tested at the house side I had no problem with my laptop auto
negotiating the speed at 100F. We left the site and later the customer
called after installing a router. No internet. When I log into the SM I
could see if flapping on the SM side. So we set it to 10F on the SM side and
they get an internet connection. 

 

Fast forward a few weeks and they call today to tell me how terrible the
service is. Router needs to be reset and then they get internet for a while.
Its slow, wont stream amazon, so on. No one was at the house during the call
to troubleshoot however. always helpful. 

 

Anyway with the SM set to 10F you can just log in and see it flap from link
to no link. Is there some stats on the 450 platform that would show if this
is happening?

 

Any thoughts are helpful.

 