It should be under statistics->ethernet
You can always put a switch right at the POE, and call it a day.
bp
<part15sbs{at}gmail{dot}com>
On 12/26/2016 10:22 AM, Brandon Yuchasz wrote:
Here is the background. I have a 450i SM and the Ethernet run is 302
feet from the barn to the house. Power supply is on the far end of the
Ethernet at the barn side and the poe side of the run is probably
another 50 feet. The other end of the 302 foot is in the customers
house plugged into the router. This is the longest run we have ever
done and I had some concerns but when I tested at the house side I had
no problem with my laptop auto negotiating the speed at 100F. We left
the site and later the customer called after installing a router. No
internet. When I log into the SM I could see if flapping on the SM
side. So we set it to 10F on the SM side and they get an internet
connection.
Fast forward a few weeks and they call today to tell me how terrible
the service is. Router needs to be reset and then they get internet
for a while. Its slow, wont stream amazon, so on. No one was at the
house during the call to troubleshoot however� always helpful.
Anyway with the SM set to 10F you can just log in and see it flap from
link to no link. Is there some stats on the 450 platform that would
show if this is happening?
Any thoughts are helpful�
Thanks,
Brandon