We use the GIGE-POE-APC on 100% of our network infrastructure.  We have
over 100 APs, and countless backhauls running on these.  I have every
flavor of UBNT running on these surge suppressors, and have never had a
single issue.  We have AC gear, AirFibers, M-series, you name it.

On Tue, Mar 7, 2017 at 9:58 AM, Chuck McCown <[email protected]> wrote:

> I received the following from a distributor (from one of their customers)
> this morning:
>
>
> We have some issues with their GigE suppressors with Mikrotik Routers and
> UBNT AC gear. Using the combination of the 3 we generate sever FCS errors
> on these links, which causes issues. If we bypass suppression, these links
> run clear and without issue.
>
>
>
> I have not heard of this before.  We made some improvements that helped
> ePMP and 450 gear, but nothing like this.  Many times odd  issues like this
> are due to noise coming through the ground.
>
>
>
> I will attempt to replicate this once I know the exact gear to get.  I
> wish the customer would just loan me the gear with the problem but I don’t
> know who the customer is.
>