You only have two options, if it is hermetically sealed then it does not need a drain. A casting like that with the seals it has should be hermetically sealed. Obviously it is not. Or it is defective.
So the other choice is a decent drain hole with something in it to keep bugs out. Screen works. I have seen a stainless steel type of steel wool used. From: Kurt Fankhauser Sent: Monday, June 12, 2017 12:59 PM To: [email protected] Subject: Re: [AFMUG] 450AP water intrusion prevention the bushing can be taken out, I was leaning more towards drilling a 1/4 inch hole beside it in the metal for a new drain hole. Should I pro-actively be doing this to all my APs? On Mon, Jun 12, 2017 at 11:29 AM, Seth Mattinen <[email protected]> wrote: On 6/12/17 07:27, Chuck McCown wrote: Is the little bushing looking thing second from the right the vent? Looks like it would allow a quarter inch of water to build up before draining. Can that be taken out? If so, take it out and glue some non metallic window screen over the hole. The bushing thing is probably the old FSK port.