I did most of the crimp on ends..... they are solder ends as it turns out.. ends would have to be replaced anyway
On Jul 10, 2017 9:55 PM, "Adam Moffett" <[email protected]> wrote: > LMR 400 is perfectly good for the IF cable on a split system licensed > backhaul. I would re-use it without reservation. I might just tweak the > connector to make sure someone didn't half ass it and it doesn't fall apart > in my hand. > > > > ------ Original Message ------ > From: "Steve Jones" <[email protected]> > To: [email protected] > Sent: 7/10/2017 10:27:45 PM > Subject: [AFMUG] Lmr400 vs heliax when lmr is there > > We used to be an all alvarion shop, so all our joints have good lmr400 > runs top to bottom. Part of contractor cleanup is to pull the lmr. We run > bbdge everywhere now, but as we get more into licenced gear odu may not be > the best choice to idu. > Im pulling it solely for pretty, if we went idu new we would go with a > heliax solution. But, as ive shown, im cheap. > Would you pull it or hold on to it? Note my warehouse is full of zero > dollar value stuff i "might need someday" already, and my sites are like > crack dens. > >