Wait, wait... John? Cambium? What?
When our ApexPlus power supplies have let the magic capacitor juice out
in the past (because of the HP ODUs running them at 100% all the time),
I've used Mean Well MDR-100-48's. They're like $30. SDRs work fine too,
but $20 is $20.
Note that you cannot mix Apex and ApexPlus POE injectors. It's not the
same pinout.
On 7/17/2017 10:40 AM, John Seaman wrote:
Yep, the one Adam references is a good choice. Any Meanwell 48V model
that has _Isolated Ground_ (very important) and provides at least
_70W_ will do.
John Seaman
Cambium Networks
*From:*Af [mailto:af-boun...@afmug.com] *On Behalf Of *Adam Moffett
*Sent:* Monday, July 17, 2017 7:38 AM
*To:* af@afmug.com
*Subject:* Re: [AFMUG] Alternate Trango Apex Plus power supply?
If it's AC to DC I like Meanwell SDR. I think you only need 50 watts
or so for a Trango, so this one has a large margin. Put a DIN rail in
your rack and you can put like 12 or 14 of these in a row.
https://power.sager.com/sdr-120-48-2526640.html?utm_source=googlemerchant&utm_medium=click&utm_campaign=power-brand&gclid=Cj0KCQjwwLHLBRDEARIsAN1A1Q5m9oBTTOpDXNIiS3WMcITjBf9_wOBRKmTQGtEBVgXBjGA2w7TSYhcaAqtOEALw_wcB
<https://na01.safelinks.protection.outlook.com/?url=https%3A%2F%2Fpower.sager.com%2Fsdr-120-48-2526640.html%3Futm_source%3Dgooglemerchant%26utm_medium%3Dclick%26utm_campaign%3Dpower-brand%26gclid%3DCj0KCQjwwLHLBRDEARIsAN1A1Q5m9oBTTOpDXNIiS3WMcITjBf9_wOBRKmTQGtEBVgXBjGA2w7TSYhcaAqtOEALw_wcB&data=02%7C01%7Cjohn.seaman%40cambiumnetworks.com%7C703603b1882e42a41d5508d4cd216f5a%7C0e263e36340946228ac818d993e76eb6%7C1%7C0%7C636358990910197469&sdata=QYBIjVMZPLQu1ESU%2Boz2M06a8%2FK8V%2FK241iuk1vyuGw%3D&reserved=0>
In attached pic near the top you can see a row of seven 240Watt units.
------ Original Message ------
From: "Jon Langeler" <jon-ispli...@michwave.net
<mailto:jon-ispli...@michwave.net>>
To: af@afmug.com <mailto:af@afmug.com>
Sent: 7/17/2017 10:25:09 AM
Subject: Re: [AFMUG] Alternate Trango Apex Plus power supply?
Yep. Any examples?
Jon Langeler
Michwave Technologies, Inc.
On Jul 17, 2017, at 10:24 AM, Adam Moffett
<dmmoff...@gmail.com <mailto:dmmoff...@gmail.com>> wrote:
Anything 48v that doesn't have a negative ground.
------ Original Message ------
From: "Jon Langeler" <jon-ispli...@michwave.net
<mailto:jon-ispli...@michwave.net>>
To: af@afmug.com <mailto:af@afmug.com>
Sent: 7/17/2017 10:17:31 AM
Subject: [AFMUG] Alternate Trango Apex Plus power supply?
Any suggestions?
Jon Langeler
Michwave Technologies, Inc.