Yeah, a bit of a stretch. We have improved them somewhat but still, that is a stretch.

-----Original Message----- From: George Skorup
Sent: Monday, October 23, 2017 7:56 PM
To: [email protected]
Subject: Re: [AFMUG] Baicells power and data connectivity

Two cat5's. One obviously to the data/WAN port. The other, two pairs
positive, two pairs negative. Nothing else. We did try a GigE-POE-SS
(top) and GigE-POE-APC (bottom). Power worked fine, but couldn't get the
etherlink link to come up. It was about 290 feet of cable. The eNBs have
built-in SS on the data port, so possibly too much loss or something
with the MTC suppressors added in.

The new eNB coming out will have a standard terminal block and two SFP
slots. I'm planning to use the Shireen DFP-1246 with that.

On 10/23/2017 8:36 PM, Josh Baird wrote:
Those of you who have Baicells deployed, how are you powering the base station?

Are you running something like 14/2 up the tower and providing -/+48VDC directly?

Ugh - I thought the eNB had SFP's, but it looks like I need to provide data over CAT5/6?



Reply via email to