Your problem is that it's a P8 AP

You can run hardware scheduling on any SM, but you need a P9 or higher to run it on the AP.


------ Original Message ------
From: "Gilbert Gutierrez" <[email protected]>
To: [email protected]
Sent: 1/10/2018 12:26:57 PM
Subject: Re: [AFMUG] OLD FSK Equipment

Telnet+> version
Software Version : CANOPY 7.3.6 Oct 24 2005   12:06:56 APAS-DES
Software Boot Version : CANOPYBOOT 3.0
FPGA Version : 051104
FPGA Features : Single,  40MHz ExtBus, DES,
Frequency Band : 5.7GHz
Hardware Platform : 8
Hardware Minor Revision : 0
Device Type : CANOPY
MIR Cap : 7000 (kbit)
CIR Cap : 20000 (kbit)

P8

On Wed, Jan 10, 2018 at 10:20 AM, Paul McCall <[email protected]> wrote:
You can actually use CNUT to make a P8 to HW scheduling

-----Original Message-----
From: Af [mailto:[email protected]] On Behalf Of Bill Prince
Sent: Wednesday, January 10, 2018 12:16 PM
To: [email protected]; Gilbert Gutierrez <[email protected]>
Subject: Re: [AFMUG] OLD FSK Equipment

How old?

If it's a P8, you're screwed. P9 and up can do HW scheduling.


bp
<part15sbs{at}gmail{dot}com>

On 1/10/2018 9:12 AM, Gilbert Gutierrez wrote:
> I am trying to convert an old FSK 100 from software scheduled to
> hardware scheduled but am hitting a wall.
>
> When I run the Advantage Platform Scheduler, here are my symptoms...
> 1. The AP is listed as Unable to Communicate/Extract info from Element > in the tool 2. When I select the element, I can run the switch but it > pauses after ftp and asks for a password. When I insert the password, > the tool responds "Completed" and the log says ERROR: Failed Telnet to
> x.x.x.x
>
> I am using CNUT 4.10. The AP and the package file are 7.3.6. I am
> wondering if I have to use a much older version CNUT. It has been so
> long since I have done this. Does anyone have pointers besides replace
> the very old equipment (I will be doing this spring)?
>
> Gilbert