I sent a request to the list last week, but I think it got eaten but the
list monsters.
Last week, I installed a Cambium Medusa at one of my sites, replacing a 450
AP. I removed the APC surge suppressor and put in a gige HV model for the
Medusa. It fires up, pings for about 20 seconds and then the whole
SyncInjector looks like it shuts down. I get a 1 blink error code.
When I take the SS out of the equation, it works fine. The only thing that
I can think of is that the switch is a 2960 Cisco 10/100 and it can't
handle the auto negotiation?

Basic layout of Network back to Switch is this:
Medusa > Cat6 100' (Tested at 1gig) > WBMFG APC SS > Packet Flux Gig
SyncInjector powered by Traco  DIN rail PSU > Data out to Cisco 2960.
Medusa is getting Sync from Sync Box Jr at Antenna location via Aux port
(UGPS power enabled)

Thanks!
Sam
-- 
-- 
*Sam Lambie*
Taosnet Wireless Tech.
575-758-7598 Office
www.Taosnet.com <http://www.newmex.com>

Reply via email to