IIRC, 1 flash = port #1 is tripped. 20 seconds sounds like boot up and
then RF initialization puts it over the edge. That's pretty odd since
Chuck has tested the GigE modules over 1A per pair. But the SS is
obviously clamping if the port is tripping.
On 3/26/2018 9:54 AM, Sam Lambie wrote:
I sent a request to the list last week, but I think it got eaten but
the list monsters.
Last week, I installed a Cambium Medusa at one of my sites, replacing
a 450 AP. I removed the APC surge suppressor and put in a gige HV
model for the Medusa. It fires up, pings for about 20 seconds and then
the whole SyncInjector looks like it shuts down. I get a 1 blink error
code.
When I take the SS out of the equation, it works fine. The only thing
that I can think of is that the switch is a 2960 Cisco 10/100 and it
can't handle the auto negotiation?
Basic layout of Network back to Switch is this:
Medusa > Cat6 100' (Tested at 1gig) > WBMFG APC SS > Packet Flux Gig
SyncInjector powered by Traco DIN rail PSU > Data out to Cisco 2960.
Medusa is getting Sync from Sync Box Jr at Antenna location via Aux
port (UGPS power enabled)
Thanks!
Sam
--
--
*Sam Lambie*
Taosnet Wireless Tech.
575-758-7598 Office
www.Taosnet.com <http://www.newmex.com>